The effect of process parameters on a continuous blending process monitored in-line by near-infrared spectroscopy

The continuous feeding-mixing system ensures the composition uniformity down to the tableting continuous manufacturing line so that a quality end-product is consistently delivered. Near-infrared spectroscopy (NIRS) enables in-line assessment of the blend's critical quality attributes in real-time. In this study, the effect of total feed rate and impeller speed on the continuous blending process monitored in-line by NIRS was examined by principal component analysis (PCA), ANOVA simultaneous component analysis (ASCA) and partial least squares (PLS) regression. Process data were generated by a factorial experimental design with process parameters and a constant formulation comprised of: 30 % (wt/wt) ibuprofen, 67.5 % (wt/wt) microcrystalline cellulose, 2 % (wt/wt) of sodium starch glycolate and 0.5 % (wt/wt) of magnesium stearate. The PCA hinted at the prevalence of impeller speed effect on ibuprofen concentration due to path length variation of the NIR light caused by the fluidized behaviour in the powder blend as a result of high speed ranges (>300 rpm). The ASCA model indicated that while both impeller speed and total feed rate effects were statistically significant (p-value=0.004), the impeller speed was the factor that contributed the most to the spectral variance (55.5 %). The PLS regression model for the ibuprofen content resulted in a RMSECV of 1.3 % (wt/wt) and showed that impeller speed was yet again the factor that exerted the major influence on spectral variance, owing to its wavelength-dependent effect that prevents common pre-processing techniques from eliminating it across the entire NIR range. The best sample presentation to the NIR probe was achieved at low impeller speed ranges (<600 rpm) and low total feed rates (<15 kg/h), such that it enhanced the PLS model ability to predict the ibuprofen concentration in the blend.

Authors

Institutions

Publication Details

Journal
European Journal of Pharmaceutical Sciences
Published
2024-08-29
DOI
https://doi.org/10.1016/j.ejps.2024.106890
Citations
5
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
1.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of process parameters on a continuous blending process monitored in-line by near-infrared spectroscopy

João A. Lopes, Tuomas Ervasti, Jarkko Ketolainen, Rute C. Dias et al.
5 citations
European Journal of Pharmaceutical Sciences
Spectroscopy and Chemometric Analyses
1.18
article

The effect of process parameters on a continuous blending process monitored in-line by near-infrared spectroscopy

João A. Lopes, Tuomas Ervasti, Jarkko Ketolainen, Rute C. Dias, Ossi Korhonen
article en
5 citations

Abstract

The continuous feeding-mixing system ensures the composition uniformity down to the tableting continuous manufacturing line so that a quality end-product is consistently delivered. Near-infrared spectroscopy (NIRS) enables in-line assessment of the blend's critical quality attributes in real-time. In this study, the effect of total feed rate and impeller speed on the continuous blending process monitored in-line by NIRS was examined by principal component analysis (PCA), ANOVA simultaneous component analysis (ASCA) and partial least squares (PLS) regression. Process data were generated by a factorial experimental design with process parameters and a constant formulation comprised of: 30 % (wt/wt) ibuprofen, 67.5 % (wt/wt) microcrystalline cellulose, 2 % (wt/wt) of sodium starch glycolate and 0.5 % (wt/wt) of magnesium stearate. The PCA hinted at the prevalence of impeller speed effect on ibuprofen concentration due to path length variation of the NIR light caused by the fluidized behaviour in the powder blend as a result of high speed ranges (>300 rpm). The ASCA model indicated that while both impeller speed and total feed rate effects were statistically significant (p-value=0.004), the impeller speed was the factor that contributed the most to the spectral variance (55.5 %). The PLS regression model for the ibuprofen content resulted in a RMSECV of 1.3 % (wt/wt) and showed that impeller speed was yet again the factor that exerted the major influence on spectral variance, owing to its wavelength-dependent effect that prevents common pre-processing techniques from eliminating it across the entire NIR range. The best sample presentation to the NIR probe was achieved at low impeller speed ranges (<600 rpm) and low total feed rates (<15 kg/h), such that it enhanced the PLS model ability to predict the ibuprofen concentration in the blend.

European Journal of Pharmaceutical SciencesVol. 202
University of Lisbon (PT), University of Eastern Finland (FI)
Instituto Superior Técnico
Openalex Percentile: Top 25%
Spectroscopy and Chemometric Analyses
1.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.