Application of the “3-2-1” body surface localization method in intertrochanteric femoral fractures: a technical note

In femoral intertrochanteric fractures, poor incision positioning may result in inaccurate intramedullary nail placement direction, which increases the difficulty of reduction and thus the size and number of incisions. Repeated intraoperative fluoroscopy not only increases the radiation exposure of the surgeon but also affects the operative outcomes. This technical note proposes a method of identifying incision positioning preoperatively using the "3-2-1" body surface localization method. This auxiliary positioning technique uses a body surface locator and the lower limb force axis. It can predict the incisions for the needle insertion point, spiral blade, and locking nails, create minimally invasive incisions, avoid incorrect incision position, facilitate accurate intraoperative intramedullary nail placement, reduce the incision size, intraoperative bleeding, and radiation exposure, and improve surgical efficiency and reduction quality.

Authors

Institutions

Publication Details

Journal
Frontiers in Surgery
Published
2024-08-29
DOI
https://doi.org/10.3389/fsurg.2024.1394575
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of the “3-2-1” body surface localization method in intertrochanteric femoral fractures: a technical note

Yangkai Xu, Xiaowei Wu, Linglan Yan, Shaochen Tu et al.
Frontiers in Surgery
Hip and Femur Fractures
article

Application of the “3-2-1” body surface localization method in intertrochanteric femoral fractures: a technical note

Yangkai Xu, Xiaowei Wu, Linglan Yan, Shaochen Tu, Yanbin Lin
article en

Abstract

In femoral intertrochanteric fractures, poor incision positioning may result in inaccurate intramedullary nail placement direction, which increases the difficulty of reduction and thus the size and number of incisions. Repeated intraoperative fluoroscopy not only increases the radiation exposure of the surgeon but also affects the operative outcomes. This technical note proposes a method of identifying incision positioning preoperatively using the "3-2-1" body surface localization method. This auxiliary positioning technique uses a body surface locator and the lower limb force axis. It can predict the incisions for the needle insertion point, spiral blade, and locking nails, create minimally invasive incisions, avoid incorrect incision position, facilitate accurate intraoperative intramedullary nail placement, reduce the incision size, intraoperative bleeding, and radiation exposure, and improve surgical efficiency and reduction quality.

Frontiers in SurgeryVol. 11
Fuzhou Second Hospital (CN)
Openalex Percentile: Top 74%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.