Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis

After the sagittal distance of the posterior edge of the prosthetic endplate was completely covered, the mechanical influence of the entire cervical spine was low. The sagittal distance at the posterior edge of the endplate of different sizes changed the motion pattern and load distribution of the implanted segment to some extent. When the sagittal distance between the prosthesis and the upper endplate was greater than or equal to 3 mm, the mechanical indices of the implanted segment increased significantly, increasing the risk of local tissue injury, especially during extension motion. Compared to the sagittal distance at the posterior edge of the endplate of the lower prosthesis, increasing the sagittal distance at the posterior edge of the endplate of the upper prosthesis has a greater effect on the mechanics of the cervical spine.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2024-08-29
DOI
https://doi.org/10.3389/fbioe.2024.1371548
Citations
2
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis

Lihua Chen, Haiyan Wang, Guangming Xu, Hao Liu
2 citations
Frontiers in Bioengineering and Biotechnology
Cervical and Thoracic Myelopathy
1.15
article

Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis

Lihua Chen, Haiyan Wang, Guangming Xu, Hao Liu
article en
2 citations

Abstract

After the sagittal distance of the posterior edge of the prosthetic endplate was completely covered, the mechanical influence of the entire cervical spine was low. The sagittal distance at the posterior edge of the endplate of different sizes changed the motion pattern and load distribution of the implanted segment to some extent. When the sagittal distance between the prosthesis and the upper endplate was greater than or equal to 3 mm, the mechanical indices of the implanted segment increased significantly, increasing the risk of local tissue injury, especially during extension motion. Compared to the sagittal distance at the posterior edge of the endplate of the lower prosthesis, increasing the sagittal distance at the posterior edge of the endplate of the upper prosthesis has a greater effect on the mechanics of the cervical spine.

Frontiers in Bioengineering and BiotechnologyVol. 12
Guangzhou University of Chinese Medicine (CN), Guangxi University of Chinese Medicine (CN), Shenzhen Pingle Orthopedic Hospital (CN)
Openalex Percentile: Top 21%
Cervical and Thoracic Myelopathy
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis — Lihua Chen, Haiyan Wang, et al. · Frontiers in Bioengineering and Biotechnology (2024) | TGRS Research Map | TGRS