Study of quinine hydrochloride detection using boron-doped diamond electrodes

This study investigates the electrochemical properties of quinine hydrochloride (QH) using boron-doped diamond (BDD) electrodes. The redox behavior of QH was analyzed and compared in phosphate buffer solution (PBS) and potassium perchlorate (KClO 4 ) electrolyte, observing an increase in current response with hydrogen-terminated BDD (H-BDD) electrodes. A cyclic voltammogram of QH in 0.1 M PBS and 0.1 M KClO 4 shows a reduction peak at −1.14 V ( vs. Ag/AgCl ). The scan rate dependence was examined to understand the reduction mechanism involving two electrons. A linear calibration curve was noted from 2 μM to 25 μM range (R 2 = 0.99) with detection limits of 0.18 μM in PBS and 0.16 μM in KClO 4 . The BDD electrodes demonstrated good selectivity in tonic water with sharp oxidation potentials for QH, confirming their stability for QH detection.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-08-29
DOI
https://doi.org/10.1016/j.ijoes.2024.100778
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of quinine hydrochloride detection using boron-doped diamond electrodes

Yunita Triana, Gusti Umindya Nur Tajalla, Yasuaki Einaga, Genki Ogata et al.
5 citations
International Journal of Electrochemical Science
Electrochemical sensors and biosensors
1.04
article

Study of quinine hydrochloride detection using boron-doped diamond electrodes

Yunita Triana, Gusti Umindya Nur Tajalla, Yasuaki Einaga, Genki Ogata, Muhammad Raihan Ramadhan, Dewi Umaningrum, Meutya Dwi Leoriza, Nessa Sabriena, Andi Idhil Ismail
article en
5 citations

Abstract

This study investigates the electrochemical properties of quinine hydrochloride (QH) using boron-doped diamond (BDD) electrodes. The redox behavior of QH was analyzed and compared in phosphate buffer solution (PBS) and potassium perchlorate (KClO 4 ) electrolyte, observing an increase in current response with hydrogen-terminated BDD (H-BDD) electrodes. A cyclic voltammogram of QH in 0.1 M PBS and 0.1 M KClO 4 shows a reduction peak at −1.14 V ( vs. Ag/AgCl ). The scan rate dependence was examined to understand the reduction mechanism involving two electrons. A linear calibration curve was noted from 2 μM to 25 μM range (R 2 = 0.99) with detection limits of 0.18 μM in PBS and 0.16 μM in KClO 4 . The BDD electrodes demonstrated good selectivity in tonic water with sharp oxidation potentials for QH, confirming their stability for QH detection.

International Journal of Electrochemical ScienceVol. 19(10)
Keio University (JP), Institut Teknologi Kalimantan (ID), Lambung Mangkurat University (ID)
Clean water and sanitation
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of quinine hydrochloride detection using boron-doped diamond electrodes — Yunita Triana, Gusti Umindya Nur Tajalla, et al. · International Journal of Electrochemical Science (2024) | TGRS Research Map | TGRS