Noise-robust analysis of X-Ray absorption near-edge structure based on poisson distribution

We demonstrate that the noise tolerance of X-ray absorption near-edge structure (XANES) analysis can be improved by reconsidering the noise model. XANES measurement is a powerful technique to investigate the structure and electronic state of materials. In XANES measurements, the incident photon number and the absorbed photon number are measured, and the ratio of the two (called the absorption factor) is analyzed. The conventional analytical method involves fitting by the least-squares method, in which the stochastic noise is assumed to conform to a Gaussian distribution. We propose a framework for XANES analysis using a Poisson distribution as a likelihood model, focusing on the number of absorbed photons rather than the absorption factor. We validate the effectiveness of our method in numerical experiments. Moreover, we apply our method to actual solid electrolyte material data and demonstrate its practicality.

Authors

Institutions

Publication Details

Journal
Science and Technology of Advanced Materials Methods
Published
2024-08-29
DOI
https://doi.org/10.1080/27660400.2024.2397939
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise-robust analysis of X-Ray absorption near-edge structure based on poisson distribution

Hiroyuki Kumazoe, Ichiro Akai, Kenji Nagata, Shuhei Kashiwamura et al.
1 citations
Science and Technology of Advanced Materials Methods
Medical Imaging Techniques and Applications
0.40
article

Noise-robust analysis of X-Ray absorption near-edge structure based on poisson distribution

Hiroyuki Kumazoe, Ichiro Akai, Kenji Nagata, Shuhei Kashiwamura, Toshihiro Okajima, Kazunori Iwamitsu, Masato Okada, Shun Katakami, Taiga Yamasaki
article en
1 citations

Abstract

We demonstrate that the noise tolerance of X-ray absorption near-edge structure (XANES) analysis can be improved by reconsidering the noise model. XANES measurement is a powerful technique to investigate the structure and electronic state of materials. In XANES measurements, the incident photon number and the absorbed photon number are measured, and the ratio of the two (called the absorption factor) is analyzed. The conventional analytical method involves fitting by the least-squares method, in which the stochastic noise is assumed to conform to a Gaussian distribution. We propose a framework for XANES analysis using a Poisson distribution as a likelihood model, focusing on the number of absorbed photons rather than the absorption factor. We validate the effectiveness of our method in numerical experiments. Moreover, we apply our method to actual solid electrolyte material data and demonstrate its practicality.

Science and Technology of Advanced Materials MethodsVol. 4(1)
Hitotsubashi University (JP), Bunkyo University (JP), National Institute for Materials Science (JP), Japan Synchrotron Radiation Research Institute (JP), Kumamoto Industrial Research Institute (JP), Aichi Synchrotron Radiation Center, The University of Tokyo (JP), Nara Institute of Science and Technology (JP), Kumamoto University (JP)
Japan Society for the Promotion of Science, Core Research for Evolutional Science and Technology
Openalex Percentile: Top 36%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.