New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma

The current paper reports two new, robust, and efficient conditions for electromembrane extraction of acidic substances from human plasma. Two systems were developed based on eutectic solvents: A1 ("A" for acid) comprised dodecyl methyl sulfoxide and thymol in 1:2 ratio (w/w) as liquid membrane, while A2 used [6-methylcoumarin:thymol (1:2)]:2-nitrophenyl octyl ether in 2:1 ratio (w/w). The performance of A1 and A2 was characterized by extraction of 31 acidic model analytes (pharmaceutical drugs and nutrients) spiked into 100 µL human plasma diluted 1:1 (v/v) with phosphate buffer pH 7.4. The acceptor solution was 50 mM NH<sub>4</sub>HCO<sub>3</sub> buffer pH 10.0, and extraction was performed at an agitation rate of 750 RPM. Voltage and extraction time were 30 V for 30 min and 10 V for 20 min for A1 and A2, respectively. Under optimal conditions, A1 extracted analytes with 1.8 ≤ log P ≤ 6.0 with an average recovery (R) of 85.1%, while A2 extracted in a range of 0.5 ≤ log P ≤ 6.0 with an average recovery of 79.9%. Meanwhile, extraction current was low at 9 and 26 µA, respectively, which is indicative of good system robustness. Using UHPLC-MS/MS analysis of the acceptor solution, repeatability of the A1 and A2 methods was determined to be 2.8-7.7% and 3.3-9.4% for R > 40%, matrix effects were 82-117% and 84-112%, respectively, and linear calibration curves were obtained. The performance and compatibility with human plasma represent a major improvement over previous state-of-the-art liquid membranes for acidic analytes, namely 1-octanol.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2024-08-29
DOI
https://doi.org/10.1007/s00216-024-05503-6
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma

Grete Hasvold, Anne Oldeide Hay, Samira Dowlatshah, Frederik André Hansen et al.
3 citations
Analytical and Bioanalytical Chemistry
Analytical chemistry methods development
0.71
article

New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma

Grete Hasvold, Anne Oldeide Hay, Samira Dowlatshah, Frederik André Hansen, Chenchen Song, Somayeh Gaznawi
article en
3 citations

Abstract

The current paper reports two new, robust, and efficient conditions for electromembrane extraction of acidic substances from human plasma. Two systems were developed based on eutectic solvents: A1 ("A" for acid) comprised dodecyl methyl sulfoxide and thymol in 1:2 ratio (w/w) as liquid membrane, while A2 used [6-methylcoumarin:thymol (1:2)]:2-nitrophenyl octyl ether in 2:1 ratio (w/w). The performance of A1 and A2 was characterized by extraction of 31 acidic model analytes (pharmaceutical drugs and nutrients) spiked into 100 µL human plasma diluted 1:1 (v/v) with phosphate buffer pH 7.4. The acceptor solution was 50 mM NH<sub>4</sub>HCO<sub>3</sub> buffer pH 10.0, and extraction was performed at an agitation rate of 750 RPM. Voltage and extraction time were 30 V for 30 min and 10 V for 20 min for A1 and A2, respectively. Under optimal conditions, A1 extracted analytes with 1.8 ≤ log P ≤ 6.0 with an average recovery (R) of 85.1%, while A2 extracted in a range of 0.5 ≤ log P ≤ 6.0 with an average recovery of 79.9%. Meanwhile, extraction current was low at 9 and 26 µA, respectively, which is indicative of good system robustness. Using UHPLC-MS/MS analysis of the acceptor solution, repeatability of the A1 and A2 methods was determined to be 2.8-7.7% and 3.3-9.4% for R > 40%, matrix effects were 82-117% and 84-112%, respectively, and linear calibration curves were obtained. The performance and compatibility with human plasma represent a major improvement over previous state-of-the-art liquid membranes for acidic analytes, namely 1-octanol.

Analytical and Bioanalytical ChemistryVol. 417(7)
University of Oslo (NO), Henan University of Technology (CN)
Universitetet i Oslo
Clean water and sanitation
Openalex Percentile: Top 35%
Analytical chemistry methods development
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.