Thermoacoustic Imaging Using Single-Channel Data Acquisition System for Non-Invasive Assessment of Liver Microwave Ablation: A Feasibility Study

Microwave ablation (MWA) plays a crucial role in non-surgical liver cancer treatment, but the existing efficacy evaluation tools lack the characteristics of being real-time, non-invasive, and efficient. As an emerging imaging technology, thermoacoustic imaging (TAI) has attracted extensive clinical attention for its excellent merits, which combine the advantages of high contrast in microwave imaging and high resolution in ultrasound imaging. Particularly, the application of a circular scanned single-channel data acquisition system maximizes the capture of thermoacoustic signals, thereby providing more comprehensive image information and rendering reconstructed images closer to reality. This study aimed to verify the feasibility of TAI in non-invasive evaluation of the efficacy of MWA on ex vivo porcine liver and in vivo rabbit liver. During the experiments, ultrasound is used to cross-verify the results of TAI to ensure the accuracy and reliability of the method. Additionally, by altering the thickness of porcine liver tissue to increase the distance (from 0 mm to 80 mm) between the horn antenna and the target (soy sauce tube), TAI is used to observe the change of the image signal-to-noise ratio to preliminarily explore the imaging depth of TAI. The results of ex and in vivo experiments can not only promote the clinical application of TAI, but also be expected to provide a more accurate and reliable efficacy assessment method for MWA in liver cancer treatment.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-08-29
DOI
https://doi.org/10.3390/photonics11090807
Citations
3
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermoacoustic Imaging Using Single-Channel Data Acquisition System for Non-Invasive Assessment of Liver Microwave Ablation: A Feasibility Study

Wanting Peng, Lin Huang, Ling Song, Qiang Lu et al.
3 citations
Photonics
Photoacoustic and Ultrasonic Imaging
0.55
article

Thermoacoustic Imaging Using Single-Channel Data Acquisition System for Non-Invasive Assessment of Liver Microwave Ablation: A Feasibility Study

Wanting Peng, Lin Huang, Ling Song, Qiang Lu, Yan Luo, Lian Feng, Zeqi Yang
article en
3 citations

Abstract

Microwave ablation (MWA) plays a crucial role in non-surgical liver cancer treatment, but the existing efficacy evaluation tools lack the characteristics of being real-time, non-invasive, and efficient. As an emerging imaging technology, thermoacoustic imaging (TAI) has attracted extensive clinical attention for its excellent merits, which combine the advantages of high contrast in microwave imaging and high resolution in ultrasound imaging. Particularly, the application of a circular scanned single-channel data acquisition system maximizes the capture of thermoacoustic signals, thereby providing more comprehensive image information and rendering reconstructed images closer to reality. This study aimed to verify the feasibility of TAI in non-invasive evaluation of the efficacy of MWA on ex vivo porcine liver and in vivo rabbit liver. During the experiments, ultrasound is used to cross-verify the results of TAI to ensure the accuracy and reliability of the method. Additionally, by altering the thickness of porcine liver tissue to increase the distance (from 0 mm to 80 mm) between the horn antenna and the target (soy sauce tube), TAI is used to observe the change of the image signal-to-noise ratio to preliminarily explore the imaging depth of TAI. The results of ex and in vivo experiments can not only promote the clinical application of TAI, but also be expected to provide a more accurate and reliable efficacy assessment method for MWA in liver cancer treatment.

PhotonicsVol. 11(9)
Southwest University of Science and Technology (CN), University of Electronic Science and Technology of China (CN), Sichuan University (CN), West China Hospital of Sichuan University (CN)
West China Hospital, Sichuan University
Good health and well-being
Openalex Percentile: Top 37%
Photoacoustic and Ultrasonic Imaging
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.