Measurement of Axial Length in the Calculation of Intraocular Lens Power for Biometry

Background: Intraocular Lenses (IOLS) are permanent artificial lenses that can replace the eye's natural lens to restore both near and distant vision. The aim of the study is to compare the accuracy of a single high quality. A scan measurement with that of the average three acceptable measurements in the calculation of IOL power. Materials and methods: Studied 180 eyes of 180 patients who underwent IOL surgery. All these patients underwent preoperative ocular biometry. Phacosurgery with posterior chamber intra ocular lens (PC IOL) implantation and clinical refraction was done in all patients between 4 to 12 weeks post operatively. The duration of the study was from January 2018 to December 2020 at Chittagong Parkview Hospital Ltd, Chattogram. Results: There was no significant difference between the two study group in measured axial length calculated emmertopic IOL power and the prediction of post operative refraction. Conclusion: The use of single high quality axial length measurement was as accurate as the mean of the three acceptable axial length measurement in the calculation of IOL power. IAHS Medical Journal Vol 6(1), June 2023; 30-33

Authors

Institutions

Publication Details

Journal
IAHS Medical Journal
Published
2024-08-29
DOI
https://doi.org/10.3329/iahsmj.v6i1.75543
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Axial Length in the Calculation of Intraocular Lens Power for Biometry

Md Zainal Abedin, Balayat Hossain Dhali
IAHS Medical Journal
Intraocular Surgery and Lenses
article

Measurement of Axial Length in the Calculation of Intraocular Lens Power for Biometry

Md Zainal Abedin, Balayat Hossain Dhali
article en

Abstract

Background: Intraocular Lenses (IOLS) are permanent artificial lenses that can replace the eye's natural lens to restore both near and distant vision. The aim of the study is to compare the accuracy of a single high quality. A scan measurement with that of the average three acceptable measurements in the calculation of IOL power. Materials and methods: Studied 180 eyes of 180 patients who underwent IOL surgery. All these patients underwent preoperative ocular biometry. Phacosurgery with posterior chamber intra ocular lens (PC IOL) implantation and clinical refraction was done in all patients between 4 to 12 weeks post operatively. The duration of the study was from January 2018 to December 2020 at Chittagong Parkview Hospital Ltd, Chattogram. Results: There was no significant difference between the two study group in measured axial length calculated emmertopic IOL power and the prediction of post operative refraction. Conclusion: The use of single high quality axial length measurement was as accurate as the mean of the three acceptable axial length measurement in the calculation of IOL power. IAHS Medical Journal Vol 6(1), June 2023; 30-33

IAHS Medical JournalVol. 6(1)
Rangamati Science and Technology University (BD)
Openalex Percentile: Top 75%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.