Metasurface Absorber for Blood Hemoglobin Concentration

In this study, a biosensing scenario is developed for monitoring blood quality based on the detection of blood hemoglobin concentration. The procedure involves considering the blood sample as the dielectric with different refractive indexes for different concentrations of hemoglobin. Usually, the sensitivity to design parameters is the major issue with the metasurface-based detection. To address this issue, a three-layer graphene-based wave absorber is designed and modeled using passive circuit elements. The major idea behind this work is to maximize the device sensitivity against the blood sample. The research methodology involves impedance matching between the device and the surrounding environment, while full-wave simulation is also performed and compared to ensure circuit view accuracy. The findings suggest that the proposed graphene-based absorber can efficiently monitor blood quality via dual absorption peaks. The simulation results extracted from impedance matching and the full-wave method indicate frequency shifts of the second absorption peak. These shift values are interpreted based on hemoglobin concentration. Additionally, ample analyses are provided to show the reliability of the proposed absorber against geometrical aspects, incident angle, external stimulation, and the graphene electron relaxation time.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2024-08-29
DOI
https://doi.org/10.1021/acsabm.4c00512
Citations
20
Primary Topic
Metamaterials and Metasurfaces Applications
Type
article
Field-Weighted Citation Impact
2.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metasurface Absorber for Blood Hemoglobin Concentration

Ava Salmanpour, Behnaz Rashidi, Ali Soldoozy, Toktam Aghaee et al.
20 citations
ACS Applied Bio Materials
Metamaterials and Metasurfaces Applications
2.36
article

Metasurface Absorber for Blood Hemoglobin Concentration

Ava Salmanpour, Behnaz Rashidi, Ali Soldoozy, Toktam Aghaee, Ilghar Rezaei
article en
20 citations

Abstract

In this study, a biosensing scenario is developed for monitoring blood quality based on the detection of blood hemoglobin concentration. The procedure involves considering the blood sample as the dielectric with different refractive indexes for different concentrations of hemoglobin. Usually, the sensitivity to design parameters is the major issue with the metasurface-based detection. To address this issue, a three-layer graphene-based wave absorber is designed and modeled using passive circuit elements. The major idea behind this work is to maximize the device sensitivity against the blood sample. The research methodology involves impedance matching between the device and the surrounding environment, while full-wave simulation is also performed and compared to ensure circuit view accuracy. The findings suggest that the proposed graphene-based absorber can efficiently monitor blood quality via dual absorption peaks. The simulation results extracted from impedance matching and the full-wave method indicate frequency shifts of the second absorption peak. These shift values are interpreted based on hemoglobin concentration. Additionally, ample analyses are provided to show the reliability of the proposed absorber against geometrical aspects, incident angle, external stimulation, and the graphene electron relaxation time.

ACS Applied Bio MaterialsVol. 7(9)
Isfahan University of Technology (IR), Shahid Chamran University of Ahvaz (IR), Islamic Azad University Central Tehran Branch (IR), Islamic Azad University, Yazd (IR), Semnan University (IR)
Openalex Percentile: Top 10%
Metamaterials and Metasurfaces Applications
2.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Metasurface Absorber for Blood Hemoglobin Concentration — Ava Salmanpour, Behnaz Rashidi, et al. · ACS Applied Bio Materials (2024) | TGRS Research Map | TGRS