Numerical Performance Evaluation of Aqueous LiCl and CaCl2 Solutions as Liquid Desiccants in Dehumidification Systems

This study aimed to determine the transfer performance of aqueous LiCl and CaCl2 liquid desiccants by numerical means. This research was conducted numerically by simultaneously solving heat and mass transfer equations explicitly using the finite difference method, with the changes in property values of the liquid desiccant in each control volume. The differences in fluid characteristics and property values between the aqueous LiCl and CaCl2 solutions remarkably affected the reduction water content from the air. When using the CaCl2 solution, performance decreased by 15% compared to the LiCl solution. The temperature of the liquid desiccant increased by around 13%.

Authors

Institutions

Publication Details

Published
2024-08-29
DOI
https://doi.org/10.3390/engproc2024067024
Citations
2
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Performance Evaluation of Aqueous LiCl and CaCl2 Solutions as Liquid Desiccants in Dehumidification Systems

Hifni Mukhtar Ariyadi, Joko Waluyo, Nico Ndaru Pratama, Wahyu Hayatullah
2 citations
Adsorption and Cooling Systems
0.43
article

Numerical Performance Evaluation of Aqueous LiCl and CaCl2 Solutions as Liquid Desiccants in Dehumidification Systems

Hifni Mukhtar Ariyadi, Joko Waluyo, Nico Ndaru Pratama, Wahyu Hayatullah
article en
2 citations

Abstract

This study aimed to determine the transfer performance of aqueous LiCl and CaCl2 liquid desiccants by numerical means. This research was conducted numerically by simultaneously solving heat and mass transfer equations explicitly using the finite difference method, with the changes in property values of the liquid desiccant in each control volume. The differences in fluid characteristics and property values between the aqueous LiCl and CaCl2 solutions remarkably affected the reduction water content from the air. When using the CaCl2 solution, performance decreased by 15% compared to the LiCl solution. The temperature of the liquid desiccant increased by around 13%.

Universitas Gadjah Mada (ID)
Openalex Percentile: Top 43%
Adsorption and Cooling Systems
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.