Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding System Versus Standard Lead Aprons

Introduction Significant progress in the field of interventional cardiology has led to a rise in percutaneous procedures and an increase in the risk of radiation exposure at the workplace. Staff health has been put at risk due to the limitations of conventional radiation protective techniques. Innovative methods, such as RAMPART, have promising prospects for enhancing radiation safety. The purpose of this study was to evaluate RAMPART's effectiveness and practicality in comparison to conventional protective techniques with a lead apron and shield (LAS) during cardiac interventional procedures. Method One hundred elective cardiac procedures were enrolled in this prospective single-center research study. Two groups were formed from the participants: standard protection (group A) and RAMPAT system (group B). Real-time dosimeters were used to track the radiation dosage, dosage reduction factor, dosage reduction percentage, and likelihood of exceeding the limit, which were included in the data. Proceduralists were urged to use different strategies to reduce exposure. The study was approved by an ethical committee and ran from June 2023 to August 2023. Results When comparing the RAMPART group to the conventional protection group, neck-level radiation exposure was considerably lower for all workers. There were no notable variations in the exposure of the waist. The RAMPART group was shown to be superior in minimizing radiation exposure, as evidenced by dose reduction metrics. The groups had comparable procedural characteristics. Conclusion Compared to conventional LAS, the RAMPART system dramatically reduces radiation exposure to the entire body.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-08-29
DOI
https://doi.org/10.7759/cureus.68108
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding System Versus Standard Lead Aprons

Tarique Shahzad Chachar, Husam A. Noor, Noof Althawadi, Sara Al Raisi et al.
Cureus
Radiation Dose and Imaging
article

Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding System Versus Standard Lead Aprons

Tarique Shahzad Chachar, Husam A. Noor, Noof Althawadi, Sara Al Raisi, Nooraldaem Yousif, Zaina Noor, Nouf AlAnsari
article en

Abstract

Introduction Significant progress in the field of interventional cardiology has led to a rise in percutaneous procedures and an increase in the risk of radiation exposure at the workplace. Staff health has been put at risk due to the limitations of conventional radiation protective techniques. Innovative methods, such as RAMPART, have promising prospects for enhancing radiation safety. The purpose of this study was to evaluate RAMPART's effectiveness and practicality in comparison to conventional protective techniques with a lead apron and shield (LAS) during cardiac interventional procedures. Method One hundred elective cardiac procedures were enrolled in this prospective single-center research study. Two groups were formed from the participants: standard protection (group A) and RAMPAT system (group B). Real-time dosimeters were used to track the radiation dosage, dosage reduction factor, dosage reduction percentage, and likelihood of exceeding the limit, which were included in the data. Proceduralists were urged to use different strategies to reduce exposure. The study was approved by an ethical committee and ran from June 2023 to August 2023. Results When comparing the RAMPART group to the conventional protection group, neck-level radiation exposure was considerably lower for all workers. There were no notable variations in the exposure of the waist. The RAMPART group was shown to be superior in minimizing radiation exposure, as evidenced by dose reduction metrics. The groups had comparable procedural characteristics. Conclusion Compared to conventional LAS, the RAMPART system dramatically reduces radiation exposure to the entire body.

CureusVol. 16(8)
Khalifa University of Science and Technology (AE)
Openalex Percentile: Top 77%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding System Versus Standard Lead Aprons — Tarique Shahzad Chachar, Husam A. Noor, et al. · Cureus (2024) | TGRS Research Map | TGRS