Incidental Findings Following Dental Implant Procedures in the Mandible: A New Post-Processing CBCT Software Analysis

<b>Background/Objectives</b>: The aim of this study was to evaluate incidental findings in the mandible after the placement of dental implants using a new cone-beam computed tomography (CBCT) software. <b>Methods</b>: The initial sample consisted of 2872 CBCT scans of patients of both sexes. The parameters evaluated in this study were the location of the implants in the mandible, implant length, anatomical relationship of the implant with the mandibular canal, presence or absence of damage to the adjacent teeth, presence or absence of implant fractures, and presence or absence of bone support. Fisher's exact test was performed to compare the variables. The significance level was set at <i>p</i> = 0.05. <b>Results</b>: Out of 2872 CBCT scans, 214 images of patients with an average age of 44.5 years were included. The most frequent location of the implants was the posterior region (93.5%), with 54% of the implants having a length between 9 and 14 mm. It was found that 92% of the implants were positioned above the mandibular canal. Damage to adjacent teeth was observed, with no correlation with the implant positioning (<i>p</i> = 1.000). In 100% of cases of implants in the anterior region, there was bone support. Fracture was observed in 1.7% of implants with a length between 9 and 14 mm. <b>Conclusions</b>: The installation of implants in the mandible occurs more frequently in the posterior region, with a high presence of bone support and a low incidence of damage to adjacent teeth, anatomical structures, and fractures.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-08-29
DOI
https://doi.org/10.3390/diagnostics14171908
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incidental Findings Following Dental Implant Procedures in the Mandible: A New Post-Processing CBCT Software Analysis

Marcel da Silva Garrote, Cyntia Rodrigues de Araújo Estrela, Orlando Aguirre Guedes, Ana Helena Gonçalves de Alencar et al.
Diagnostics
Dental Radiography and Imaging
article

Incidental Findings Following Dental Implant Procedures in the Mandible: A New Post-Processing CBCT Software Analysis

Marcel da Silva Garrote, Cyntia Rodrigues de Araújo Estrela, Orlando Aguirre Guedes, Ana Helena Gonçalves de Alencar, Mike Reis Bueno, Lucas Rodrigues de Araújo Estrela, Carlos Estrela
article en

Abstract

<b>Background/Objectives</b>: The aim of this study was to evaluate incidental findings in the mandible after the placement of dental implants using a new cone-beam computed tomography (CBCT) software. <b>Methods</b>: The initial sample consisted of 2872 CBCT scans of patients of both sexes. The parameters evaluated in this study were the location of the implants in the mandible, implant length, anatomical relationship of the implant with the mandibular canal, presence or absence of damage to the adjacent teeth, presence or absence of implant fractures, and presence or absence of bone support. Fisher's exact test was performed to compare the variables. The significance level was set at <i>p</i> = 0.05. <b>Results</b>: Out of 2872 CBCT scans, 214 images of patients with an average age of 44.5 years were included. The most frequent location of the implants was the posterior region (93.5%), with 54% of the implants having a length between 9 and 14 mm. It was found that 92% of the implants were positioned above the mandibular canal. Damage to adjacent teeth was observed, with no correlation with the implant positioning (<i>p</i> = 1.000). In 100% of cases of implants in the anterior region, there was bone support. Fracture was observed in 1.7% of implants with a length between 9 and 14 mm. <b>Conclusions</b>: The installation of implants in the mandible occurs more frequently in the posterior region, with a high presence of bone support and a low incidence of damage to adjacent teeth, anatomical structures, and fractures.

DiagnosticsVol. 14(17)
Universidade Estadual de Goiás (BR), Universidade Federal de Goiás (BR), Universidade Estadual Paulista (Unesp) (BR)
Life below water
Openalex Percentile: Top 79%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.