What Mistakes Can Be Made When Performing the Electrical Cardioversion Procedure?—Analysis of Emergency Medical Team Performance during the Championships in Emergency Medicine
Teams participating in the assessed tasks in a significant majority of cases correctly qualified the patient for EC, and correctly carried out the actions required for this procedure. It is of particular note that with every subsequent shock, the percentage of shocks carried out without the sync mode increased significantly.
Authors
- Michał Szlagor (ORCID: https://orcid.org/0000-0002-9020-3252)
- Mieczysław Dutka (ORCID: https://orcid.org/0000-0002-0396-1873)
- Michał Ćwiertnia (ORCID: https://orcid.org/0000-0001-9576-8095)
- Marek Kawecki (ORCID: https://orcid.org/0000-0001-9925-5297)
- Arkadiusz Stasicki (ORCID: https://orcid.org/0000-0002-4754-7308)
- M. Hajduga (ORCID: https://orcid.org/0000-0001-5499-482X)
- Rafał Bobiński (ORCID: https://orcid.org/0000-0002-3649-5653)
- Tomasz Ilczak (ORCID: https://orcid.org/0000-0003-2478-9045)
- Monika Mikulska (ORCID: https://orcid.org/0000-0002-5412-010X)
- Piotr Białoń (ORCID: https://orcid.org/0000-0002-9744-2678)
Institutions
- University of Bielsko-Biała (PL)
Publication Details
- Journal
- Healthcare
- Published
- 2024-08-29
- DOI
- https://doi.org/10.3390/healthcare12171724
- Primary Topic
- Cardiac Arrest and Resuscitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00