Software-Defined Radio-Based Sensing for Breathing Monitoring: Design, Challenges, and Performance Evaluation

Software defined radio frequency (SDRF) sensing technology has revolutionized healthcare by enabling real-time monitoring and early diagnosis of patient health status with higher reliability, diagnostic accuracy, and enhanced healthcare services in a noncontact and noninvasive manner. However, RF sensing for breathing disorder diagnosis and monitoring is still an open research challenge. Further research is necessary to determine RF sensing accuracy and reliability for breathing disorders in different environments and applications. RF sensing is sensitive to environmental changes and shows nonlinear responses. Existing studies have explored RF sensing for breathing monitoring using fixed RF parameters to evaluate the system’s performance. However, several key parameters in RF sensing, such as operating frequency, sampling rate, bandwidth, gain, power, the height of antennas, and distance between transmitter and receiver, affect the system’s performance practicality. In this article, we used a reconfigurable SDRF sensing system to evaluate the RF parameters for monitoring breathing in order to understand their effects and enhance the performance of the sensing system. The correlation between RF sensing characteristics and wearable breathing sensors is evaluated using the correlation coefficient (CC) and mean square error (MSE). The findings reveal that a higher operating frequency of 4.8 GHz, a sampling rate of 300 samples/s, antennas on the line of sight, and distance up to 2 feet show the best performance, with an MSE of less than 0.1111 and a CC of 0.9943, indicating a significant correlation. The experimental study concludes that breathing monitoring performance using RF sensing heavily depends on RF parameters.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-08-29
DOI
https://doi.org/10.1109/jsen.2024.3443419
Citations
2
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Software-Defined Radio-Based Sensing for Breathing Monitoring: Design, Challenges, and Performance Evaluation

Najah AbuAli, Mobeen Ur Rehman, Mohammad Hayajneh, Mohammed Hussain et al.
2 citations
IEEE Sensors Journal
Wireless Body Area Networks
0.37
article

Software-Defined Radio-Based Sensing for Breathing Monitoring: Design, Challenges, and Performance Evaluation

Najah AbuAli, Mobeen Ur Rehman, Mohammad Hayajneh, Mohammed Hussain, Muhammad Bilal Khan, Kil To Chong, Farman Ullah
article en
2 citations

Abstract

Software defined radio frequency (SDRF) sensing technology has revolutionized healthcare by enabling real-time monitoring and early diagnosis of patient health status with higher reliability, diagnostic accuracy, and enhanced healthcare services in a noncontact and noninvasive manner. However, RF sensing for breathing disorder diagnosis and monitoring is still an open research challenge. Further research is necessary to determine RF sensing accuracy and reliability for breathing disorders in different environments and applications. RF sensing is sensitive to environmental changes and shows nonlinear responses. Existing studies have explored RF sensing for breathing monitoring using fixed RF parameters to evaluate the system’s performance. However, several key parameters in RF sensing, such as operating frequency, sampling rate, bandwidth, gain, power, the height of antennas, and distance between transmitter and receiver, affect the system’s performance practicality. In this article, we used a reconfigurable SDRF sensing system to evaluate the RF parameters for monitoring breathing in order to understand their effects and enhance the performance of the sensing system. The correlation between RF sensing characteristics and wearable breathing sensors is evaluated using the correlation coefficient (CC) and mean square error (MSE). The findings reveal that a higher operating frequency of 4.8 GHz, a sampling rate of 300 samples/s, antennas on the line of sight, and distance up to 2 feet show the best performance, with an MSE of less than 0.1111 and a CC of 0.9943, indicating a significant correlation. The experimental study concludes that breathing monitoring performance using RF sensing heavily depends on RF parameters.

IEEE Sensors JournalVol. 24(21)
COMSATS University Islamabad (PK), Khalifa University of Science and Technology (AE), United Arab Emirates University (AE), Jeonbuk National University (KR), Zayed University (AE)
United Arab Emirates University
Climate action
Openalex Percentile: Top 44%
Wireless Body Area Networks
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.