Radiological and clinical outcomes after Attune primary total knee arthroplasty using Stemmable Tibia: A two-year follow-up prospective bi-center study

This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. Radiological outcomes (hip-knee-ankle axis and medial proximal tibial angle) were assessed preoperatively and postoperatively. Clinical outcomes (visual analog scale score, Hospital for Special Surgery score, Knee Society function score, Knee Society knee score, flexion contracture, further flexion, and range of motion) were analyzed preoperatively and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Complications (periprosthetic joint infection and aseptic loosening) were examined. The hip-knee-ankle axis decreased (preoperative: 9.5° ± 6.3°, postoperative: 1.1° ± 2.7°), whereas the medial proximal tibial angle increased (preoperative: 84.6° ± 4.1°, postoperative: 89.8° ± 1.9°). The visual analog scale score, Hospital for Special Surgery score, Knee Society knee score, and Knee Society function score increased postoperatively. The Knee Society knee score indicated above good outcomes (100.0% and 99.0% at 1 and 2 years postoperatively, respectively). The Knee Society function score also showed above good results (98.0% and 93.0% at 1 and 2 years postoperatively, respectively). The range of motion significantly improved (p < 0.001): flexion contracture decreased from 9.10° ± 7.23° to 2.15° ± 2.87°, whereas further flexion increased from 136.05° ± 14.78° to 139.80° ± 10.02°. One patient developed periprosthetic joint infection; no early loosening was observed. In conclusion, Attune primary total knee arthroplasty with Stemmable Tibia not only is safe and effective but also leads to radiological and clinical improvements.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-08-29
DOI
https://doi.org/10.1371/journal.pone.0309015
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiological and clinical outcomes after Attune primary total knee arthroplasty using Stemmable Tibia: A two-year follow-up prospective bi-center study

Chankue Park, Sang-Min Lee, Seung Joon Rhee, Mi Sook Yun et al.
PLoS ONE
Total Knee Arthroplasty Outcomes
article

Radiological and clinical outcomes after Attune primary total knee arthroplasty using Stemmable Tibia: A two-year follow-up prospective bi-center study

Chankue Park, Sang-Min Lee, Seung Joon Rhee, Mi Sook Yun, Seung Hun Woo, Jung Shin Kim
article en

Abstract

This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. Radiological outcomes (hip-knee-ankle axis and medial proximal tibial angle) were assessed preoperatively and postoperatively. Clinical outcomes (visual analog scale score, Hospital for Special Surgery score, Knee Society function score, Knee Society knee score, flexion contracture, further flexion, and range of motion) were analyzed preoperatively and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Complications (periprosthetic joint infection and aseptic loosening) were examined. The hip-knee-ankle axis decreased (preoperative: 9.5° ± 6.3°, postoperative: 1.1° ± 2.7°), whereas the medial proximal tibial angle increased (preoperative: 84.6° ± 4.1°, postoperative: 89.8° ± 1.9°). The visual analog scale score, Hospital for Special Surgery score, Knee Society knee score, and Knee Society function score increased postoperatively. The Knee Society knee score indicated above good outcomes (100.0% and 99.0% at 1 and 2 years postoperatively, respectively). The Knee Society function score also showed above good results (98.0% and 93.0% at 1 and 2 years postoperatively, respectively). The range of motion significantly improved (p < 0.001): flexion contracture decreased from 9.10° ± 7.23° to 2.15° ± 2.87°, whereas further flexion increased from 136.05° ± 14.78° to 139.80° ± 10.02°. One patient developed periprosthetic joint infection; no early loosening was observed. In conclusion, Attune primary total knee arthroplasty with Stemmable Tibia not only is safe and effective but also leads to radiological and clinical improvements.

PLoS ONEVol. 19(8)
Pusan National University Hospital (KR), Pusan National University Yangsan Hospital (KR), Pusan National University (KR)
Pusan National University
Good health and well-being
Openalex Percentile: Top 74%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.