Power System Frequency Estimation With Zero Response Time Under Abrupt Transients

The methods based on Discrete Fourier Transform (DFT) are the mainstream approaches for frequency estimation of signals in power systems. However, they exhibit unfavorable long response times when confronted with signals experiencing abrupt transients, such as amplitude or phase step changes. To surmount this challenge, a novel methodology leveraging the DFT has been designed to estimate power system signals with accuracy and responsiveness under abrupt transient conditions. The method first constructs the correlation between DFT bins and each parameter. The relationship is then harnessed to derive an unbiased estimator for sine-wave with a known step position. Afterward, we introduce a step position estimation procedure that guarantees the robustness of the estimator when dealing with abrupt transients. As a result, the proposed method achieves zero response time when confronted with arbitrary abrupt transients without loss of accuracy. The effectiveness and responsiveness of our method are evaluated through simulations that adhere to the stringent requirements of P-class phasor measurement units.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Circuits and Systems I Regular Papers
Published
2024-08-29
DOI
https://doi.org/10.1109/tcsi.2024.3447703
Citations
4
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power System Frequency Estimation With Zero Response Time Under Abrupt Transients

Xusheng Tang, Feiyang Zhong, Jian Song, Qing Yao et al.
4 citations
IEEE Transactions on Circuits and Systems I Regular Papers
Power System Optimization and Stability
0.83
article

Power System Frequency Estimation With Zero Response Time Under Abrupt Transients

Xusheng Tang, Feiyang Zhong, Jian Song, Qing Yao, Lu Tang, Kai Wang, Zichuan Yu
article en
4 citations

Abstract

The methods based on Discrete Fourier Transform (DFT) are the mainstream approaches for frequency estimation of signals in power systems. However, they exhibit unfavorable long response times when confronted with signals experiencing abrupt transients, such as amplitude or phase step changes. To surmount this challenge, a novel methodology leveraging the DFT has been designed to estimate power system signals with accuracy and responsiveness under abrupt transient conditions. The method first constructs the correlation between DFT bins and each parameter. The relationship is then harnessed to derive an unbiased estimator for sine-wave with a known step position. Afterward, we introduce a step position estimation procedure that guarantees the robustness of the estimator when dealing with abrupt transients. As a result, the proposed method achieves zero response time when confronted with arbitrary abrupt transients without loss of accuracy. The effectiveness and responsiveness of our method are evaluated through simulations that adhere to the stringent requirements of P-class phasor measurement units.

IEEE Transactions on Circuits and Systems I Regular PapersVol. 72(1)
Hunan University (CN), Southeast University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 27%
Power System Optimization and Stability
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.