Determination of the Effect of Harmonics on the Performance of Single-Phase Low Voltage kWh Meters

Low-voltage installation systems with 450 VA and 900 VA power are one of the most commonly used electricity distribution systems in Indonesia. In the previous study, adjustments to the load of household needs were clearly made, and measurements were made at the load of 450-900 VA because some users received payment subsidies. Two types of kWh meters in accordance with standards in Indonesia are used by testing the readings of analog and digital kWh meters, which are loaded according to the load pattern. The load used is varied based on the load pattern that has been described in Table IV. Installation evaluation in the form of installing filters and improving the cross-sectional area value is carried out. After the installation of the passive filter, the power quality at 450 VA and 900 VA full load conditions improved, with the power factor in the electrical system of the 450 VA home installation increasing from 0.916 to 1. Keywords: harmonics, kWh meter, electrical energy, non-linear load, Home Installation

Authors

Institutions

Publication Details

Journal
International Journal of Research and Review
Published
2024-08-19
DOI
https://doi.org/10.52403/ijrr.20240833
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Effect of Harmonics on the Performance of Single-Phase Low Voltage kWh Meters

Mochammad Facta, Susatyo Handoko, Yudha Aditya Nugraha
International Journal of Research and Review
Smart Grid Energy Management
article

Determination of the Effect of Harmonics on the Performance of Single-Phase Low Voltage kWh Meters

Mochammad Facta, Susatyo Handoko, Yudha Aditya Nugraha
article en

Abstract

Low-voltage installation systems with 450 VA and 900 VA power are one of the most commonly used electricity distribution systems in Indonesia. In the previous study, adjustments to the load of household needs were clearly made, and measurements were made at the load of 450-900 VA because some users received payment subsidies. Two types of kWh meters in accordance with standards in Indonesia are used by testing the readings of analog and digital kWh meters, which are loaded according to the load pattern. The load used is varied based on the load pattern that has been described in Table IV. Installation evaluation in the form of installing filters and improving the cross-sectional area value is carried out. After the installation of the passive filter, the power quality at 450 VA and 900 VA full load conditions improved, with the power factor in the electrical system of the 450 VA home installation increasing from 0.916 to 1. Keywords: harmonics, kWh meter, electrical energy, non-linear load, Home Installation

International Journal of Research and ReviewVol. 11(8)
Diponegoro University (ID)
Affordable and clean energy
Openalex Percentile: Top 89%
Smart Grid Energy Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of the Effect of Harmonics on the Performance of Single-Phase Low Voltage kWh Meters — Mochammad Facta, Susatyo Handoko, et al. · International Journal of Research and Review (2024) | TGRS Research Map | TGRS