Accuracy improvement of resonant sensor by an additional electrode in the measurement of liquid density and viscosity

Purpose In the measurement of liquid density and viscosity, the change of resonance parameters due to the parasitic parallel capacitance of resonator affects the measurement accuracy. To improve the accuracy, a method was proposed to compensate the parasitic parallel capacitance of resonator by adding an electrode. Design/methodology/approach The new electrode (compensation electrode) was added into resonant sensor to make compensation capacitance. The closer the compensation capacitance was to the parasitic parallel capacitance, the better compensation was. The structural parameters of resonant sensor with the compensation electrode were determined by the simulation and experiment. Findings The effect of this method was examined by the experiment. The relative errors of density and viscosity were less than 0.15, 0.5 % and standard deviations were less than 0.0004 g/cm 3 and 0.005 mPas, respectively. Practical implications The experimental results show that this method is valuable for the parasitic parallel capacitance compensation of immersed resonant sensor. Originality/value This paper has not been published in other journals.

Authors

Publication Details

Journal
Sensor Review
Published
2024-08-20
DOI
https://doi.org/10.1108/sr-04-2024-0289
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy improvement of resonant sensor by an additional electrode in the measurement of liquid density and viscosity

Hyon Chol Kim, Hyon Jang, Chunghun Kim, Un Hyang Ri et al.
Sensor Review
Analytical Chemistry and Sensors
article

Accuracy improvement of resonant sensor by an additional electrode in the measurement of liquid density and viscosity

Hyon Chol Kim, Hyon Jang, Chunghun Kim, Un Hyang Ri, Nam Chol An
article en

Abstract

Purpose In the measurement of liquid density and viscosity, the change of resonance parameters due to the parasitic parallel capacitance of resonator affects the measurement accuracy. To improve the accuracy, a method was proposed to compensate the parasitic parallel capacitance of resonator by adding an electrode. Design/methodology/approach The new electrode (compensation electrode) was added into resonant sensor to make compensation capacitance. The closer the compensation capacitance was to the parasitic parallel capacitance, the better compensation was. The structural parameters of resonant sensor with the compensation electrode were determined by the simulation and experiment. Findings The effect of this method was examined by the experiment. The relative errors of density and viscosity were less than 0.15, 0.5 % and standard deviations were less than 0.0004 g/cm 3 and 0.005 mPas, respectively. Practical implications The experimental results show that this method is valuable for the parasitic parallel capacitance compensation of immersed resonant sensor. Originality/value This paper has not been published in other journals.

Sensor ReviewVol. 44(6)
Affordable and clean energy
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.