Cavity-enhanced light-induced thermoelastic spectroscopy for trace-gas sensing

We report a trace gas sensing technique of cavity-enhanced light-induced thermoelastic spectroscopy (CE-LITES) with a Fabry-Pérot (F-P) optical cavity and a high-quality-factor resonant quartz tuning fork (QTF). Pound-Drever-Hall (PDH) locking method is used to lock the laser to the optical cavity. With only a short 9-cm optical cavity (finesse, ∼1283) and a tiny commercially available standard QTF (Q-factor, ∼38910), a CE-LITES sensor for acetylene detection was developed to demonstrate this technique, achieving a minimum detection limit (MDL) of 7.5 parts-per-billion (ppb) for a 216-s integration time and a normalized noise equivalent absorption (NNEA) coefficient of as low as 1.91 × 10<sup>-10 </sup>cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>. The developed technique bears promising potential for sensitive and accurate measurement that is needed for studying trace gas-phase analyte.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-08-20
DOI
https://doi.org/10.1364/oe.536849
Citations
24
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
5.78

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cavity-enhanced light-induced thermoelastic spectroscopy for trace-gas sensing

Jinguang Lv, Dongqing Zhang, Mengpeng Hu, Hui Zhang et al.
24 citations
Optics Express
Spectroscopy and Laser Applications
5.78
article

Cavity-enhanced light-induced thermoelastic spectroscopy for trace-gas sensing

Jinguang Lv, Dongqing Zhang, Mengpeng Hu, Hui Zhang, Haoran Wang, Qiang Wang, Jingqiu Liang, Hongqiang Fan, Junfeng Zhou
article en
24 citations

Abstract

We report a trace gas sensing technique of cavity-enhanced light-induced thermoelastic spectroscopy (CE-LITES) with a Fabry-Pérot (F-P) optical cavity and a high-quality-factor resonant quartz tuning fork (QTF). Pound-Drever-Hall (PDH) locking method is used to lock the laser to the optical cavity. With only a short 9-cm optical cavity (finesse, ∼1283) and a tiny commercially available standard QTF (Q-factor, ∼38910), a CE-LITES sensor for acetylene detection was developed to demonstrate this technique, achieving a minimum detection limit (MDL) of 7.5 parts-per-billion (ppb) for a 216-s integration time and a normalized noise equivalent absorption (NNEA) coefficient of as low as 1.91 × 10<sup>-10 </sup>cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>. The developed technique bears promising potential for sensitive and accurate measurement that is needed for studying trace gas-phase analyte.

Optics ExpressVol. 32(19)
University of Chinese Academy of Sciences (CN)
Natural Science Foundation of Jilin Province, National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 3%
Spectroscopy and Laser Applications
5.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.