On-Site Sensor Sensitivity Adjustment Technique for a Maintenance-Free Heat Flow Monitoring in Building Systems

In this paper, an advanced solution for measuring heat flow through opaque building elements is presented. The solution is based on the implementation of a computer-aided technique for continuous monitoring of heat flow sensor performance and silent checking of their accuracy. In principle, the technique provides an ex-post compensation of potential deviations and inaccuracies detected during the measurement, which can be done without interfering with the ongoing experiment. As a consequence, traditional ‘non-smart’ sensors can be turned into advanced sensors with self-sensing or self-adjustment features at nearly zero additional costs. The high efficiency of the proposed approach was validated against experimental data obtained from an independent set of advanced high-sensitive sensors. Considering the validation results, the proposed technique brings an entirely new potential for maintenance-free applications for thermal performance monitoring in the building sector, typically for long-term experiments or measurements under dynamic environments.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-08-20
DOI
https://doi.org/10.3390/app14167323
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Site Sensor Sensitivity Adjustment Technique for a Maintenance-Free Heat Flow Monitoring in Building Systems

Robert Černý, Jan Kočí, Jiří Maděra
Applied Sciences
Building Energy and Comfort Optimization
article

On-Site Sensor Sensitivity Adjustment Technique for a Maintenance-Free Heat Flow Monitoring in Building Systems

Robert Černý, Jan Kočí, Jiří Maděra
article en

Abstract

In this paper, an advanced solution for measuring heat flow through opaque building elements is presented. The solution is based on the implementation of a computer-aided technique for continuous monitoring of heat flow sensor performance and silent checking of their accuracy. In principle, the technique provides an ex-post compensation of potential deviations and inaccuracies detected during the measurement, which can be done without interfering with the ongoing experiment. As a consequence, traditional ‘non-smart’ sensors can be turned into advanced sensors with self-sensing or self-adjustment features at nearly zero additional costs. The high efficiency of the proposed approach was validated against experimental data obtained from an independent set of advanced high-sensitive sensors. Considering the validation results, the proposed technique brings an entirely new potential for maintenance-free applications for thermal performance monitoring in the building sector, typically for long-term experiments or measurements under dynamic environments.

Applied SciencesVol. 14(16)
Czech Technical University in Prague (CZ)
Grantová Agentura České Republiky
Openalex Percentile: Top 86%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-Site Sensor Sensitivity Adjustment Technique for a Maintenance-Free Heat Flow Monitoring in Building Systems — Robert Černý, Jan Kočí, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS