Thermal behavior of adhesively bonded timber‐concrete composite slabs subjected to standard fire exposure

Abstract Fire tests were performed for the first time on adhesively bonded timber‐concrete composite slabs. The two medium‐scale (1.8 × 1.25 m) slabs were produced by gluing an 80‐mm thick three‐layer cross‐laminated timber (CLT) board to a 50 mm thick prefabricated reinforced concrete (RC) slab with epoxy and polyurethane (PUR) adhesives, respectively. The behavior of the composite slabs under elevated temperature was monitored by (1) observing the burning behavior of the used CLT, for example, charring and delamination and (2) measuring the temperature development at different locations of the CLT slabs, in the adhesive bond between concrete and timber boards, and in RC slabs. It was found that employing a one‐dimensional charring model for pure softwood, as prescribed by Eurocode 5‐1‐2, underestimated the charring depth of CLT due to the delamination effects. Measurements revealed that the average charring rates in the middle layer of CLT panels were approximately 0.65 mm/min, suggesting that the presence of concrete does not significantly affect the thermal behavior of the CLT panel. Delamination within the CLT was observed when its adhesive temperature was around 230°C. It was followed by the free‐fall of delaminated wood plies, which progressed slowly and lasted until the end of the test. At 90 min into the test, the temperatures of epoxy at the nine locations ranged between 55°C and 130°, while that of PUR between 60°C and 100°. The adhesive between concrete and CLT could lose stiffness significantly along the rising of temperature after surpassing of glass transition temperature (58°C for epoxy and 23°C for PUR in this study). The results indicated a high risk of weakening the composite action between the concrete slab and timber board. The measured temperatures of steel rebar were lower than 50°C. However, the concrete temperature reached about 120°C and the concrete cracked due to the distinct thermal expansions between concrete and timber and the rigid constraint of adhesive bond.

Authors

Institutions

Publication Details

Journal
Fire and Materials
Published
2024-08-19
DOI
https://doi.org/10.1002/fam.3235
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal behavior of adhesively bonded timber‐concrete composite slabs subjected to standard fire exposure

Qiuni Fu, Bohumil Kasal, Libo Yan, Jochen Zehfuß et al.
Fire and Materials
Fire effects on concrete materials
article

Thermal behavior of adhesively bonded timber‐concrete composite slabs subjected to standard fire exposure

Qiuni Fu, Bohumil Kasal, Libo Yan, Jochen Zehfuß, Haoze Chen, Sven Brunkhorst
article en

Abstract

Abstract Fire tests were performed for the first time on adhesively bonded timber‐concrete composite slabs. The two medium‐scale (1.8 × 1.25 m) slabs were produced by gluing an 80‐mm thick three‐layer cross‐laminated timber (CLT) board to a 50 mm thick prefabricated reinforced concrete (RC) slab with epoxy and polyurethane (PUR) adhesives, respectively. The behavior of the composite slabs under elevated temperature was monitored by (1) observing the burning behavior of the used CLT, for example, charring and delamination and (2) measuring the temperature development at different locations of the CLT slabs, in the adhesive bond between concrete and timber boards, and in RC slabs. It was found that employing a one‐dimensional charring model for pure softwood, as prescribed by Eurocode 5‐1‐2, underestimated the charring depth of CLT due to the delamination effects. Measurements revealed that the average charring rates in the middle layer of CLT panels were approximately 0.65 mm/min, suggesting that the presence of concrete does not significantly affect the thermal behavior of the CLT panel. Delamination within the CLT was observed when its adhesive temperature was around 230°C. It was followed by the free‐fall of delaminated wood plies, which progressed slowly and lasted until the end of the test. At 90 min into the test, the temperatures of epoxy at the nine locations ranged between 55°C and 130°, while that of PUR between 60°C and 100°. The adhesive between concrete and CLT could lose stiffness significantly along the rising of temperature after surpassing of glass transition temperature (58°C for epoxy and 23°C for PUR in this study). The results indicated a high risk of weakening the composite action between the concrete slab and timber board. The measured temperatures of steel rebar were lower than 50°C. However, the concrete temperature reached about 120°C and the concrete cracked due to the distinct thermal expansions between concrete and timber and the rigid constraint of adhesive bond.

Fire and MaterialsVol. 48(8)
University of Luxembourg (LU), Fraunhofer Institute for Wood Research Wilhelm-Klauditz-Institut (DE), Technische Universität Braunschweig (DE)
Bundesministerium für Bildung und Forschung, Bundesministerium für Ernährung und Landwirtschaft, Fachagentur Nachwachsende Rohstoffe, Bundesanstalt für Landwirtschaft und Ernährung
Sustainable cities and communities
Openalex Percentile: Top 84%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.