Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor

We present improvements on the adaptive optics (AO) correction method using a pyramid wavefront sensor (P-WFS) and introduce a novel approach for closed-loop focus shifting in retinal imaging. The method's efficacy is validated through <i>in vivo</i> adaptive optics optical coherence tomography (AO-OCT) imaging in both, healthy individuals and patients with diabetic retinopathy. In both study groups, a stable focusing on the anterior retinal layers is achieved. We further report on an improvement in AO loop speed that can be used to expand the imaging area of AO-OCT in the slow scanning direction, largely independent of the eye's isoplanatic patch. Our representative AO-OCT data reveal microstructural details of the neurosensory retina such as vessel walls and microglia cells that are visualized in single volume data and over an extended field of view. The excellent performance of the P-WFS based AO-OCT imaging in patients suggests good clinical applicability of this technology.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-08-20
DOI
https://doi.org/10.1364/boe.533451
Citations
4
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor

Andreas Pollreisz, Elisabeth Brunner, Daniel Jodlbauer, Wolfgang Drexler et al.
4 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
0.74
article

Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor

Andreas Pollreisz, Elisabeth Brunner, Daniel Jodlbauer, Wolfgang Drexler, Michael Pircher, Ronny Ramlau, Laura Kunze, Victoria Hutterer
article en
4 citations

Abstract

We present improvements on the adaptive optics (AO) correction method using a pyramid wavefront sensor (P-WFS) and introduce a novel approach for closed-loop focus shifting in retinal imaging. The method's efficacy is validated through <i>in vivo</i> adaptive optics optical coherence tomography (AO-OCT) imaging in both, healthy individuals and patients with diabetic retinopathy. In both study groups, a stable focusing on the anterior retinal layers is achieved. We further report on an improvement in AO loop speed that can be used to expand the imaging area of AO-OCT in the slow scanning direction, largely independent of the eye's isoplanatic patch. Our representative AO-OCT data reveal microstructural details of the neurosensory retina such as vessel walls and microglia cells that are visualized in single volume data and over an extended field of view. The excellent performance of the P-WFS based AO-OCT imaging in patients suggests good clinical applicability of this technology.

Biomedical Optics ExpressVol. 15(10)
Johannes Kepler University of Linz (AT), Johann Radon Institute for Computational and Applied Mathematics (AT), Medical University of Vienna (AT)
Roche, Austrian Science Fund
Affordable and clean energy
Openalex Percentile: Top 32%
Optical Coherence Tomography Applications
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.