Magnetic field of electrical heating cable systems of the floors for residential premises

Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a verified methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises, and assessment of compliance of the magnetic field with the normative level. Method. A methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises has been developed. Scientific novelty. Based on Bio-Savar’s law and the principle of superposition, an analytical model of the magnetic field of electric heating cable systems of the floors and its calculation method was created. The magnetic field of the coaxial heating cable is determined, taking into account the value of its maximum eccentricity. The experimentally substantiated correctness of the obtained theoretical statements, which is confirmed by their coincidence with the results of the experiment with a spread of less than 7 %. Practical significance. A verified methodology for calculating the magnetic field of electric heating cable systems of the floors was proposed and an assessment of compliance of their magnetic flux density with the normative level of 0.5 μT was performed. It is recommended to lay modern two-wire heating cables at a depth of at least 75–100 mm from the floor. With a smaller laying depth, it is recommended to use coaxial heating cables, which have an order of magnitude smaller magnetic field. References 51, tables 1, figures 11.

Authors

Publication Details

Journal
Electrical Engineering & Electromechanics
Published
2024-08-19
DOI
https://doi.org/10.20998/2074-272x.2024.5.07
Citations
2
Primary Topic
Magnetic and Electromagnetic Effects
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic field of electrical heating cable systems of the floors for residential premises

K. D. Kundius, Sergiy Reutskiy, D. Ye. Pelevin, V. Yu. Rozov
2 citations
Electrical Engineering & Electromechanics
Magnetic and Electromagnetic Effects
0.80
article

Magnetic field of electrical heating cable systems of the floors for residential premises

K. D. Kundius, Sergiy Reutskiy, D. Ye. Pelevin, V. Yu. Rozov
article en
2 citations

Abstract

Problem. In order to effectively protect public health from the magnetic field of electric heating cable systems of the floors, it is necessary to reduce it to a safe level. However, this requires careful study of the magnetic field. The purpose of the work is to develop a mathematical model and a verified methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises, and assessment of compliance of the magnetic field with the normative level. Method. A methodology for calculating the magnetic field of electric heating cable systems of the floors in residential premises has been developed. Scientific novelty. Based on Bio-Savar’s law and the principle of superposition, an analytical model of the magnetic field of electric heating cable systems of the floors and its calculation method was created. The magnetic field of the coaxial heating cable is determined, taking into account the value of its maximum eccentricity. The experimentally substantiated correctness of the obtained theoretical statements, which is confirmed by their coincidence with the results of the experiment with a spread of less than 7 %. Practical significance. A verified methodology for calculating the magnetic field of electric heating cable systems of the floors was proposed and an assessment of compliance of their magnetic flux density with the normative level of 0.5 μT was performed. It is recommended to lay modern two-wire heating cables at a depth of at least 75–100 mm from the floor. With a smaller laying depth, it is recommended to use coaxial heating cables, which have an order of magnitude smaller magnetic field. References 51, tables 1, figures 11.

Electrical Engineering & Electromechanics(5)
Openalex Percentile: Top 28%
Magnetic and Electromagnetic Effects
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic field of electrical heating cable systems of the floors for residential premises — K. D. Kundius, Sergiy Reutskiy, et al. · Electrical Engineering & Electromechanics (2024) | TGRS Research Map | TGRS