Bio-corrosion behaviors and bio-compatibilities of TiNbZrTa and TiNbZrTaMo high entropy alloys

The bio-corrosion behavior and bio-compatibility of TiNbZrTa and TiNbZrTaMo high entropy alloys (HEAs) are crucial for their efficient maintenance during biological implantation. In this work, TiNbZrTa and TiNbZrTaMo HEAs were successfully prepared via vacuum melting, with a β-type titanium alloy Ti35Nb7Zr5Ta, exhibiting good biocompatibility used as a comparison. Due to the high entropy effect of equal atomic ratios, both TiNbZrTa and TiNbZrTaMo HEAs exhibit body-centered cubic (BCC) structure and lattice distortion compared to the β titanium alloy Ti35Nb7Zr5Ta. Mo elements contribute to the formation of a new BCC phase, resulting in a white matrix rich in Ta and Mo, and a dark second phase rich in Ti, Zr, and Nb. Electrochemical test results at 37 °C shown that TiNbZrTa has a wider and more stable passivation area than TiNbZrTaMo. The XPS results shown that formation of the passive film is related to the main elements added. Ti, Nb, Ta and Mo formed oxides via the solid-liquid interface and migrate inward, while Zr is formed at the passivation film/metal substrate interface and migrates outward, finally forming the layered structure of the passivation film. Additionally, the cytotoxicity test of mouse fiber cells was carried out to evaluate the biocompatibility of the HEAs. The results shown that the cell proliferation rate of TiNbZrTa and TiNbZrTaMo HEAs reached 0 and 1, respectively, with TiNbZrTa exhibiting better biocompatibility, as adding Mo reduced the cell proliferation rate. These findings may provide a method for predicting the bio-corrosion behavior and bio-compatibility of HEAs used for biological implantation.

Authors

Institutions

Publication Details

Journal
Journal of Materials Research and Technology
Published
2024-08-20
DOI
https://doi.org/10.1016/j.jmrt.2024.08.083
Citations
10
Primary Topic
High Entropy Alloys Studies
Type
article
Field-Weighted Citation Impact
2.13

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bio-corrosion behaviors and bio-compatibilities of TiNbZrTa and TiNbZrTaMo high entropy alloys

Long Xiao, Jun Cheng, Jian Hu, Qiuming Chen et al.
10 citations
Journal of Materials Research and Technology
High Entropy Alloys Studies
2.13
article

Bio-corrosion behaviors and bio-compatibilities of TiNbZrTa and TiNbZrTaMo high entropy alloys

Long Xiao, Jun Cheng, Jian Hu, Qiuming Chen, Wanyuan Gui, Jinming Xu, Tao Wu, Guang Chen, Panyi Yang
article en
10 citations

Abstract

The bio-corrosion behavior and bio-compatibility of TiNbZrTa and TiNbZrTaMo high entropy alloys (HEAs) are crucial for their efficient maintenance during biological implantation. In this work, TiNbZrTa and TiNbZrTaMo HEAs were successfully prepared via vacuum melting, with a β-type titanium alloy Ti35Nb7Zr5Ta, exhibiting good biocompatibility used as a comparison. Due to the high entropy effect of equal atomic ratios, both TiNbZrTa and TiNbZrTaMo HEAs exhibit body-centered cubic (BCC) structure and lattice distortion compared to the β titanium alloy Ti35Nb7Zr5Ta. Mo elements contribute to the formation of a new BCC phase, resulting in a white matrix rich in Ta and Mo, and a dark second phase rich in Ti, Zr, and Nb. Electrochemical test results at 37 °C shown that TiNbZrTa has a wider and more stable passivation area than TiNbZrTaMo. The XPS results shown that formation of the passive film is related to the main elements added. Ti, Nb, Ta and Mo formed oxides via the solid-liquid interface and migrate inward, while Zr is formed at the passivation film/metal substrate interface and migrates outward, finally forming the layered structure of the passivation film. Additionally, the cytotoxicity test of mouse fiber cells was carried out to evaluate the biocompatibility of the HEAs. The results shown that the cell proliferation rate of TiNbZrTa and TiNbZrTaMo HEAs reached 0 and 1, respectively, with TiNbZrTa exhibiting better biocompatibility, as adding Mo reduced the cell proliferation rate. These findings may provide a method for predicting the bio-corrosion behavior and bio-compatibility of HEAs used for biological implantation.

Journal of Materials Research and TechnologyVol. 32
Sichuan University (CN), West China Hospital of Sichuan University (CN), Zhejiang Institute of Mechanical and Electrical Engineering (CN), First Affiliated Hospital Zhejiang University (CN), University of Science and Technology Beijing (CN)
National Natural Science Foundation of China, Huazhong University of Science and Technology, State Key Laboratory of Material Processing and Die and Mould Technology, National Key Research and Development Program of China, National Key Research and Development Program of China Stem Cell and Translational Research
Openalex Percentile: Top 14%
High Entropy Alloys Studies
2.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.