Linear Bloch–Siegert phase‐encoded low‐field MRI: RF coils, pulse sequence, and image reconstruction

Conventional <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient systems have several weaknesses including high cost and bulk. As a step towards addressing these while providing new degrees of freedom for spatial encoding and system design in Magnetic Resonance Imaging (MRI), a radio frequency (RF) gradient encoding system and pulse sequence for phase encoding using the Bloch-Siegert (BS) shift were developed. Optimized BS spatial encoding coils with bucking windings (counter-wound loops) were designed and constructed, along with compatible homogeneous imaging coils for excitation and signal reception. Two coil systems were developed: one for phantom imaging and a second for human wrist imaging. BS phase-encoded imaging and BS RF pulse simulations were performed. Pulse sequences were designed for linear stepping in k-space and implemented on a 47.5-mT scanner to image resolution phantoms in both coil setups. Reconstructions were performed using both the full <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> <mml:mrow><mml:mo>+</mml:mo></mml:mrow> </mml:msubsup> </mml:mrow> </mml:math> -based encoding fields for each BS pulse amplitude and using inverse discrete Fourier transforms. A <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient was used for frequency encoding during signal readout, and the third axis was projected. Specific absorption ratio (SAR) calculations were performed for the wrist coil to determine the safety of BS-based RF encoding for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> fields in the low field MRI regime. The optimized RF spatial encoding coils resulted in higher linearity ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow> <mml:mrow><mml:mn>2</mml:mn></mml:mrow> </mml:msup> <mml:mo>=</mml:mo> <mml:mn>0.9981</mml:mn></mml:mrow> </mml:math> and 0.9921 in the phantom and wrist coils, respectively) than coils used in previous work. The phantom and wrist imaging coils were validated in simulations and experimentally to produce a peak <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> <mml:mrow><mml:mo>+</mml:mo></mml:mrow> </mml:msubsup> <mml:mo>=</mml:mo> <mml:mn>1.35</mml:mn></mml:mrow> </mml:math> G and 0.8 G with 12-W input power, respectively, in the field-of-view (length = 11 cm) used for imaging. Nominal imaging resolutions of 5.22 and 7.21 mm were, respectively, achieved by the two-coil systems in the RF phase-encoded dimension. Coil systems, pulse sequences, and image reconstructions were developed for linear RF phase encoding using the BS shift and validated using a 47.5-mT open low field scanner, establishing a key component required for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient-free imaging at low <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> field strengths.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2024-08-26
DOI
https://doi.org/10.1002/nbm.5245
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linear Bloch–Siegert phase‐encoded low‐field MRI: RF coils, pulse sequence, and image reconstruction

William A. Grissom, Christopher E. Vaughn, Sai Abitha Srinivas, Jonathan B. Martin
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Linear Bloch–Siegert phase‐encoded low‐field MRI: RF coils, pulse sequence, and image reconstruction

William A. Grissom, Christopher E. Vaughn, Sai Abitha Srinivas, Jonathan B. Martin
article en

Abstract

Conventional <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient systems have several weaknesses including high cost and bulk. As a step towards addressing these while providing new degrees of freedom for spatial encoding and system design in Magnetic Resonance Imaging (MRI), a radio frequency (RF) gradient encoding system and pulse sequence for phase encoding using the Bloch-Siegert (BS) shift were developed. Optimized BS spatial encoding coils with bucking windings (counter-wound loops) were designed and constructed, along with compatible homogeneous imaging coils for excitation and signal reception. Two coil systems were developed: one for phantom imaging and a second for human wrist imaging. BS phase-encoded imaging and BS RF pulse simulations were performed. Pulse sequences were designed for linear stepping in k-space and implemented on a 47.5-mT scanner to image resolution phantoms in both coil setups. Reconstructions were performed using both the full <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> <mml:mrow><mml:mo>+</mml:mo></mml:mrow> </mml:msubsup> </mml:mrow> </mml:math> -based encoding fields for each BS pulse amplitude and using inverse discrete Fourier transforms. A <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient was used for frequency encoding during signal readout, and the third axis was projected. Specific absorption ratio (SAR) calculations were performed for the wrist coil to determine the safety of BS-based RF encoding for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> fields in the low field MRI regime. The optimized RF spatial encoding coils resulted in higher linearity ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow> <mml:mrow><mml:mn>2</mml:mn></mml:mrow> </mml:msup> <mml:mo>=</mml:mo> <mml:mn>0.9981</mml:mn></mml:mrow> </mml:math> and 0.9921 in the phantom and wrist coils, respectively) than coils used in previous work. The phantom and wrist imaging coils were validated in simulations and experimentally to produce a peak <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> <mml:mrow><mml:mo>+</mml:mo></mml:mrow> </mml:msubsup> <mml:mo>=</mml:mo> <mml:mn>1.35</mml:mn></mml:mrow> </mml:math> G and 0.8 G with 12-W input power, respectively, in the field-of-view (length = 11 cm) used for imaging. Nominal imaging resolutions of 5.22 and 7.21 mm were, respectively, achieved by the two-coil systems in the RF phase-encoded dimension. Coil systems, pulse sequences, and image reconstructions were developed for linear RF phase encoding using the BS shift and validated using a 47.5-mT open low field scanner, establishing a key component required for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> gradient-free imaging at low <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub><mml:mrow><mml:mi>B</mml:mi></mml:mrow> <mml:mrow><mml:mn>0</mml:mn></mml:mrow> </mml:msub> </mml:mrow> </mml:math> field strengths.

NMR in BiomedicineVol. 37(12)
Vanderbilt University (US), Case Western Reserve University (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Peace, Justice and strong institutions
Openalex Percentile: Top 77%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.