Reliability of digital filtering on surface electromyographic activity of respiratory muscles in patients with COVID-19
Introduction: Surface electromyography (sEMG) is valuable for assessing respiratory muscle activity, but the influence of electromagnetic fields can impair the accuracy of the signals. This study aims to compare the Root Mean Square (RMS) values of sEMG signals from respiratory muscles in COVID-19 patients receiving oxygen therapy in the ICU before and after digital filtering. Methods: This exploratory analysis is part of a cross-sectional study registered on ClinicalTrials.gov (NCT05572853). sEMG signals from the sternocleidomastoid, scalenus, diaphragm, and rectus abdominis muscles were recorded in COVID-19 patients receiving low-flow oxygen therapy. The RMS data were analyzed and processed using Scilab 6.1.1 software before and after applying a filter with a 60 Hz notch and a passband between 20-500 Hz. Results: 71 patients with a mean age of 55 ± 14 years, predominantly male (73.2%), were included. Muscle’s activity remained unchanged after signal filtering, showing higher RMS intensity (pre-filter/post-filter) for the scalene (14.0 ± 8.6 / 8.5 ± 6.2), sternocleidomastoid (12.0 ± 8.8 / 6.8 ± 7.8), diaphragm (11.7 ± 8.1 / 5.4 ± 7.1), and rectus abdominis (10.4 ± 4.7 / 3.1 ± 1.9) muscles. RMS attenuation was significant for all muscles (p < 0.001), with no agreement between pre- and post-filtering from Bland-Altman analysis. Conclusions: The applied digital filter attenuated RMS values while maintaining the same respiratory muscle activation, enhancing signal identification by reducing noise.
Authors
- Wagner Souza Leite (ORCID: https://orcid.org/0000-0001-5716-125X)
- Rômulo de Aquino Coelho Lins (ORCID: https://orcid.org/0000-0003-4800-9939)
- Shirley Lima Campos (ORCID: https://orcid.org/0000-0003-3079-8300)
- Emanuel Fernandes Ferreira da Silva Júnior (ORCID: https://orcid.org/0000-0002-8596-580X)
- Marcelo Renato Guerino (ORCID: https://orcid.org/0000-0002-3439-9166)
- Marilú Gomes Netto Monte da Silva (ORCID: https://orcid.org/0000-0003-2189-4739)
Institutions
- Universidade Estadual de Campinas (UNICAMP) (BR)
- Universidade Federal de Pernambuco (BR)
- University of Florida Health (US)
Publication Details
- Journal
- Cuadernos de Educación y Desarrollo
- Published
- 2024-08-26
- DOI
- https://doi.org/10.55905/cuadv16n8-132
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco
- Universidade Federal de Pernambuco
- Universidade de Pernambuco