Skin Absorbed Dose Coefficients for Human Legs from Beta Radiation as a Function of Height

External exposure to skin from beta-emitter radionuclides following severe reactor accidents or nuclear testing can result in beta burning and other health complications. The skin absorbed dose coefficient (SADC) measures the energy deposition into the skin during such accidents. The U.S. Environmental Protection Agency has published several reports to measure the possible energy deposition into the skin in such accidents. However, the most recent SADC published by Federal Guidance Report (FGR) 12 was computed only at one meter above the contaminated surface. Therefore, it was necessary to develop a model to estimate the absorbed dose coefficients for skin at different heights. In this manuscript, Geant4, a Monte Carlo simulator toolkit, was used to estimate the absorbed dose coefficients from electron sources located on the soil surface with energies ranging from 0.1 to 4 MeV. The energy deposited from primary electrons, secondary electrons, and photons in a 50 µm thick layer of epidermis tissue (Basal Cells Layer) located at a depth of 50 µm from the skin surface was estimated at several discrete heights of human leg phantom. More than 40% of the total energy deposited comes from secondary electrons and photons in energy sources of 0.1 and 0.2 MeV on average, but for higher energies, this percentage is less than 1%, which indicates primary electrons are the main source of the deposited energy in the skin. Furthermore, the results showed the energy deposited into skin closer to the ground was 50–100% higher than the previously estimated doses for 1 m above the ground. The results from Geant4 showed a great correlation (R2 = 0.972) with the FGR 12 data at one meter height, and they were aligned with the published values from FGR 12, which validated the simulation results. Therefore, the calculated dose coefficients for different energy sources and different heights could be used in radiation protection measurements.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-08-21
DOI
https://doi.org/10.3390/app14167363
Primary Topic
Effects of Radiation Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Skin Absorbed Dose Coefficients for Human Legs from Beta Radiation as a Function of Height

Mohammad Yosofvand, Rabin Dhakal, Hanna Moussa, Ali Nejat
Applied Sciences
Effects of Radiation Exposure
article

Skin Absorbed Dose Coefficients for Human Legs from Beta Radiation as a Function of Height

Mohammad Yosofvand, Rabin Dhakal, Hanna Moussa, Ali Nejat
article en

Abstract

External exposure to skin from beta-emitter radionuclides following severe reactor accidents or nuclear testing can result in beta burning and other health complications. The skin absorbed dose coefficient (SADC) measures the energy deposition into the skin during such accidents. The U.S. Environmental Protection Agency has published several reports to measure the possible energy deposition into the skin in such accidents. However, the most recent SADC published by Federal Guidance Report (FGR) 12 was computed only at one meter above the contaminated surface. Therefore, it was necessary to develop a model to estimate the absorbed dose coefficients for skin at different heights. In this manuscript, Geant4, a Monte Carlo simulator toolkit, was used to estimate the absorbed dose coefficients from electron sources located on the soil surface with energies ranging from 0.1 to 4 MeV. The energy deposited from primary electrons, secondary electrons, and photons in a 50 µm thick layer of epidermis tissue (Basal Cells Layer) located at a depth of 50 µm from the skin surface was estimated at several discrete heights of human leg phantom. More than 40% of the total energy deposited comes from secondary electrons and photons in energy sources of 0.1 and 0.2 MeV on average, but for higher energies, this percentage is less than 1%, which indicates primary electrons are the main source of the deposited energy in the skin. Furthermore, the results showed the energy deposited into skin closer to the ground was 50–100% higher than the previously estimated doses for 1 m above the ground. The results from Geant4 showed a great correlation (R2 = 0.972) with the FGR 12 data at one meter height, and they were aligned with the published values from FGR 12, which validated the simulation results. Therefore, the calculated dose coefficients for different energy sources and different heights could be used in radiation protection measurements.

Applied SciencesVol. 14(16)
Texas Tech University (US)
Affordable and clean energy
Openalex Percentile: Top 77%
Effects of Radiation Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.