Investigation and Finite Element Analysis of The Distal Weight-Bearing Implant

General Background: Osseointegration. a critical advancement in prosthetics, significantly benefits individuals with transfemoral amputations by enhancing their quality of life through innovative implant systems. Specific Background: The study examines a novel distal weight-bearing implant from 17 global systems, featuring a composite nanocoating of hydroxyapatite and silica, evaluated through finite element analysis and mechanical testing. Knowledge Gap: Research on nanocoating's impact on mechanical performance and its integration into advanced prosthetic designs is limited, despite extensive exploration of various implant systems. Aims: The study evaluates the distal weight-bearing implant's effectiveness, focusing on the nanocoating's role in shock absorption and mechanical stability during various gait cycle phases. Results: The design process involved creating a Ti-6Al-4V femoral stem and UHMWPE spacer, with the implant subjected to FEA under gait cycle conditions. Nanocoated samples demonstrated effective shock absorption, though with slightly reduced mechanical properties. The implant’s performance was evaluated for heel strike, midstance, and pre-swing phases, showing adequate load-bearing capacity within safe thresholds. Novelty: This study introduces a detailed analysis of nanocoating impacts on implant performance and integrates biomechanical forces into FEA for enhanced prosthetic design evaluation. Implications: Research indicates nanocoating enhances shock absorption, but further studies are needed to balance mechanical properties with biocompatibility and biological response, potentially improving amputee care outcomes. Highlights: Advanced Implant Design: Transition from transfemoral to knee disarticulation. Nanocoating Impact: Enhances shock absorption; minor mechanical property reduction. FEA Results: Confirms load-bearing capacity through gait cycle phases. Keywords: osseointegration, distal weight-bearing implant, nanocoating, finite element analysis, gait cycle

Authors

Institutions

Publication Details

Journal
Academia Open
Published
2024-08-12
DOI
https://doi.org/10.21070/acopen.9.2024.9510
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation and Finite Element Analysis of The Distal Weight-Bearing Implant

M Mahdi, Dunya Abdulsahib Hamdi
Academia Open
Orthopaedic implants and arthroplasty
article

Investigation and Finite Element Analysis of The Distal Weight-Bearing Implant

M Mahdi, Dunya Abdulsahib Hamdi
article en

Abstract

General Background: Osseointegration. a critical advancement in prosthetics, significantly benefits individuals with transfemoral amputations by enhancing their quality of life through innovative implant systems. Specific Background: The study examines a novel distal weight-bearing implant from 17 global systems, featuring a composite nanocoating of hydroxyapatite and silica, evaluated through finite element analysis and mechanical testing. Knowledge Gap: Research on nanocoating's impact on mechanical performance and its integration into advanced prosthetic designs is limited, despite extensive exploration of various implant systems. Aims: The study evaluates the distal weight-bearing implant's effectiveness, focusing on the nanocoating's role in shock absorption and mechanical stability during various gait cycle phases. Results: The design process involved creating a Ti-6Al-4V femoral stem and UHMWPE spacer, with the implant subjected to FEA under gait cycle conditions. Nanocoated samples demonstrated effective shock absorption, though with slightly reduced mechanical properties. The implant’s performance was evaluated for heel strike, midstance, and pre-swing phases, showing adequate load-bearing capacity within safe thresholds. Novelty: This study introduces a detailed analysis of nanocoating impacts on implant performance and integrates biomechanical forces into FEA for enhanced prosthetic design evaluation. Implications: Research indicates nanocoating enhances shock absorption, but further studies are needed to balance mechanical properties with biocompatibility and biological response, potentially improving amputee care outcomes. Highlights: Advanced Implant Design: Transition from transfemoral to knee disarticulation. Nanocoating Impact: Enhances shock absorption; minor mechanical property reduction. FEA Results: Confirms load-bearing capacity through gait cycle phases. Keywords: osseointegration, distal weight-bearing implant, nanocoating, finite element analysis, gait cycle

Academia OpenVol. 9(2)
Nahrain University (IQ)
Openalex Percentile: Top 74%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.