Myocardial Fibrosis Quantification Methods by Cardiovascular Magnetic Resonance Imaging in Patients with Fabry Disease

<b>Background/Objectives</b>: The presence of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) in patients with Fabry disease (FD) is a predictor of adverse cardiac events. The aim of this study was to establish the most reliable and reproducible technique for quantifying LGE in patients with FD. <b>Methods</b>: Twenty FD patients with LGE who underwent CMR on the same scanner and LGE sequence were included. LGE quantifications were done using gray-scale thresholds of 2, 3, 4, 5 and 6 standard deviations (SD) above the mean signal intensity of the remote myocardium, the full width at half maximum method (FWHM), visual assessment with threshold (VAT) and the fully manual method (MM). <b>Results</b>: The mean amount of fibrosis varied between quantification techniques from 36 ± 19 at 2SD to 2 ± 2 g using the FWHM (<i>p</i> < 0.0001). Intraobserver reliability was excellent for most methods, except for the FWHM which was good (ICC 0.84; all <i>p</i> < 0.05). Interobserver reliability was excellent for VAT (ICC 0.94) and good for other techniques (all <i>p</i> < 0.05). Intraobserver reproducibility showed the lowest coefficient of variation (CV, 6%) at 5SD and at 2SD and VAT (35% and 38%) for interobserver reproducibility. The FWHM revealed the highest CV (63% and 94%) for both intra- and interobserver reproducibility. <b>Conclusions</b>: The available methods for LGE quantification demonstrate good to excellent intra- and interobserver reproducibility in patients with FD. The most reliable and reproducible techniques were VAT and 5SD, whereas the FWHM was the least reliable in the setting of our study. The total amount of LGE varies strongly with the quantification technique used.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-08-26
DOI
https://doi.org/10.3390/jcm13175047
Citations
2
Primary Topic
Cardiomyopathy and Myosin Studies
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Myocardial Fibrosis Quantification Methods by Cardiovascular Magnetic Resonance Imaging in Patients with Fabry Disease

Robert Manka, Wojciech Kosmala, Justyna M. Sokolska, L.P. Weber et al.
2 citations
Journal of Clinical Medicine
Cardiomyopathy and Myosin Studies
0.80
article

Myocardial Fibrosis Quantification Methods by Cardiovascular Magnetic Resonance Imaging in Patients with Fabry Disease

Robert Manka, Wojciech Kosmala, Justyna M. Sokolska, L.P. Weber, Hatem Alkadhi, Mateusz Sokolski, Mihály Károlyi, Mareike Gastl, Dana R. Hiestand, Christiane Gruner
article en
2 citations

Abstract

<b>Background/Objectives</b>: The presence of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) in patients with Fabry disease (FD) is a predictor of adverse cardiac events. The aim of this study was to establish the most reliable and reproducible technique for quantifying LGE in patients with FD. <b>Methods</b>: Twenty FD patients with LGE who underwent CMR on the same scanner and LGE sequence were included. LGE quantifications were done using gray-scale thresholds of 2, 3, 4, 5 and 6 standard deviations (SD) above the mean signal intensity of the remote myocardium, the full width at half maximum method (FWHM), visual assessment with threshold (VAT) and the fully manual method (MM). <b>Results</b>: The mean amount of fibrosis varied between quantification techniques from 36 ± 19 at 2SD to 2 ± 2 g using the FWHM (<i>p</i> < 0.0001). Intraobserver reliability was excellent for most methods, except for the FWHM which was good (ICC 0.84; all <i>p</i> < 0.05). Interobserver reliability was excellent for VAT (ICC 0.94) and good for other techniques (all <i>p</i> < 0.05). Intraobserver reproducibility showed the lowest coefficient of variation (CV, 6%) at 5SD and at 2SD and VAT (35% and 38%) for interobserver reproducibility. The FWHM revealed the highest CV (63% and 94%) for both intra- and interobserver reproducibility. <b>Conclusions</b>: The available methods for LGE quantification demonstrate good to excellent intra- and interobserver reproducibility in patients with FD. The most reliable and reproducible techniques were VAT and 5SD, whereas the FWHM was the least reliable in the setting of our study. The total amount of LGE varies strongly with the quantification technique used.

Journal of Clinical MedicineVol. 13(17)
University of Zurich (CH), Wroclaw Medical University (PL), University Hospital of Zurich (CH), Heinrich Heine University Düsseldorf (DE)
European Society of Cardiology, Universitätsspital Zürich, Narodowa Agencja Wymiany Akademickiej
Openalex Percentile: Top 24%
Cardiomyopathy and Myosin Studies
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.