A Novel Data-Driven Approach with a Long Short-Term Memory Autoencoder Model with a Multihead Self-Attention Deep Learning Model for Wind Turbine Converter Fault Detection

The imminent depletion of oil resources and increasing environmental pollution have driven the use of clean energy, particularly wind energy. However, wind turbines (WTs) face significant challenges, such as critical component failures, which can cause unexpected shutdowns and affect energy production. To address this challenge, we analyzed the Supervisory Control and Data Acquisition (SCADA) data to identify significant differences between the relationship of variables based on data reconstruction errors between actual and predicted values. This study proposes a hybrid short- and long-term memory autoencoder model with multihead self-attention (LSTM-MA-AE) for WT converter fault detection. The proposed model identifies anomalies in the data by comparing the reconstruction errors of the variables involved. However, more is needed. To address this model limitation, we developed a fault prediction system that employs an adaptive threshold with an Exponentially Weighted Moving Average (EWMA) and a fixed threshold. This system analyzes the anomalies of several variables and generates fault warnings in advance time. Thus, we propose an outlier detection method through data preprocessing and unsupervised learning, using SCADA data collected from a wind farm located in complex terrain, including real faults in the converter. The LSTM-MA-AE is shown to be able to predict the converter failure 3.3 months in advance, and with an F1 greater than 90% in the tests performed. The results provide evidence of the potential of the proposed model to improve converter fault diagnosis with SCADA data in complex environments, highlighting its ability to increase the reliability and efficiency of WTs.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-08-23
DOI
https://doi.org/10.3390/app14177458
Citations
10
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
3.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Data-Driven Approach with a Long Short-Term Memory Autoencoder Model with a Multihead Self-Attention Deep Learning Model for Wind Turbine Converter Fault Detection

Marcelo Valdiviezo-Condolo, Jorge Maldonado-Correa, Estefanía Artigao, Emilio Gómez‐Lázaro et al.
10 citations
Applied Sciences
Machine Fault Diagnosis Techniques
3.28
article

A Novel Data-Driven Approach with a Long Short-Term Memory Autoencoder Model with a Multihead Self-Attention Deep Learning Model for Wind Turbine Converter Fault Detection

Marcelo Valdiviezo-Condolo, Jorge Maldonado-Correa, Estefanía Artigao, Emilio Gómez‐Lázaro, Sergio Martín‐Martínez, Joel Torres-Cabrera
article en
10 citations

Abstract

The imminent depletion of oil resources and increasing environmental pollution have driven the use of clean energy, particularly wind energy. However, wind turbines (WTs) face significant challenges, such as critical component failures, which can cause unexpected shutdowns and affect energy production. To address this challenge, we analyzed the Supervisory Control and Data Acquisition (SCADA) data to identify significant differences between the relationship of variables based on data reconstruction errors between actual and predicted values. This study proposes a hybrid short- and long-term memory autoencoder model with multihead self-attention (LSTM-MA-AE) for WT converter fault detection. The proposed model identifies anomalies in the data by comparing the reconstruction errors of the variables involved. However, more is needed. To address this model limitation, we developed a fault prediction system that employs an adaptive threshold with an Exponentially Weighted Moving Average (EWMA) and a fixed threshold. This system analyzes the anomalies of several variables and generates fault warnings in advance time. Thus, we propose an outlier detection method through data preprocessing and unsupervised learning, using SCADA data collected from a wind farm located in complex terrain, including real faults in the converter. The LSTM-MA-AE is shown to be able to predict the converter failure 3.3 months in advance, and with an F1 greater than 90% in the tests performed. The results provide evidence of the potential of the proposed model to improve converter fault diagnosis with SCADA data in complex environments, highlighting its ability to increase the reliability and efficiency of WTs.

Applied SciencesVol. 14(17)
Universidad Nacional de Loja (EC), University of Castilla-La Mancha (ES)
European Commission, Ministerio de Economía y Competitividad, Junta de Comunidades de Castilla-La Mancha
Openalex Percentile: Top 8%
Machine Fault Diagnosis Techniques
3.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.