Application of objective optical quality analysis system in guiding early posterior capsule opacification laser treatment: An observational study

In the present study, we aimed to demonstrate the objective guiding role of objective scatter index (OSI) in patients with early stage posterior capsule opacification (PCO), especially in patients with multifocal intraocular lens (IOL) implantation. A prospective randomized case analysis was conducted on elderly patients experiencing PCO, exhibiting best-corrected visual acuity (BCVA) below 0.2 LogMAR. Exclusion criteria comprised patients with diabetes, glaucoma, high myopia, trauma, endothelial dystrophy, maculopathy or prior eye surgery affecting visual acuity. The main observational indicators were patient gender, age, post-cataract surgery duration, BCVA (LogMAR), and OSI values. For patients undergoing laser posterior capsulotomy, meticulous documentation of pre-laser OSI values and post-laser OSI values was undertaken. Subjective visual quality was then compared using the Chinese version visual function index-14 (VF-14-CN). The study comprised 65 eyes from 56 patients. PCO developed, on average, 2.06 ± 0.94 years (ranging from 0.5 to 4 years) after the initial surgery, with the OSI consistently exceeding 3.0. Among these cases, only 40 eyes underwent laser posterior capsulotomy using Nd:YAG laser, including 26 eyes implanted with monofocal IOLs and 14 eyes implanted with multifocal IOLs. Following laser posterior capsulotomy for early-stage secondary cataracts, there was a significant decrease in OSI values compared to the presurgery state, coupled with a notable increase in VF-14-CN scores. Among the 14 cases with multifocal IOL implantation, pre-laser VF-14-CN scores were lower compared to those with monofocal IOLs. Post-laser posterior capsulotomy, patients reported a marked improvement in self-perceived symptoms. The OQAS functioned as an objective assessment metric for the laser treatment of early stage PCO. In cases involving multifocal IOL implantation, the visual disturbance caused by PCO was more pronounced, underscoring the significance of OSI as a valuable guide for laser treatment in these patients.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2024-08-23
DOI
https://doi.org/10.1097/md.0000000000039386
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of objective optical quality analysis system in guiding early posterior capsule opacification laser treatment: An observational study

Dongyan Xu, Qin Wu, Hui Zhang, Jing Wang
Medicine
Intraocular Surgery and Lenses
article

Application of objective optical quality analysis system in guiding early posterior capsule opacification laser treatment: An observational study

Dongyan Xu, Qin Wu, Hui Zhang, Jing Wang
article en

Abstract

In the present study, we aimed to demonstrate the objective guiding role of objective scatter index (OSI) in patients with early stage posterior capsule opacification (PCO), especially in patients with multifocal intraocular lens (IOL) implantation. A prospective randomized case analysis was conducted on elderly patients experiencing PCO, exhibiting best-corrected visual acuity (BCVA) below 0.2 LogMAR. Exclusion criteria comprised patients with diabetes, glaucoma, high myopia, trauma, endothelial dystrophy, maculopathy or prior eye surgery affecting visual acuity. The main observational indicators were patient gender, age, post-cataract surgery duration, BCVA (LogMAR), and OSI values. For patients undergoing laser posterior capsulotomy, meticulous documentation of pre-laser OSI values and post-laser OSI values was undertaken. Subjective visual quality was then compared using the Chinese version visual function index-14 (VF-14-CN). The study comprised 65 eyes from 56 patients. PCO developed, on average, 2.06 ± 0.94 years (ranging from 0.5 to 4 years) after the initial surgery, with the OSI consistently exceeding 3.0. Among these cases, only 40 eyes underwent laser posterior capsulotomy using Nd:YAG laser, including 26 eyes implanted with monofocal IOLs and 14 eyes implanted with multifocal IOLs. Following laser posterior capsulotomy for early-stage secondary cataracts, there was a significant decrease in OSI values compared to the presurgery state, coupled with a notable increase in VF-14-CN scores. Among the 14 cases with multifocal IOL implantation, pre-laser VF-14-CN scores were lower compared to those with monofocal IOLs. Post-laser posterior capsulotomy, patients reported a marked improvement in self-perceived symptoms. The OQAS functioned as an objective assessment metric for the laser treatment of early stage PCO. In cases involving multifocal IOL implantation, the visual disturbance caused by PCO was more pronounced, underscoring the significance of OSI as a valuable guide for laser treatment in these patients.

MedicineVol. 103(34)
Fourth People’s Hospital of Jinan (CN), Xian Yang Central Hospital (CN)
Openalex Percentile: Top 76%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.