The performance and complications of long peripheral venous catheters: A retrospective single‐centre study
The overall incidence rate of catheter removal was 95.8/1000 catheter days, and the most common causes of catheter failure were phlebitis, infiltration and unintended catheter removal. The use of the cephalic vein was significantly associated with catheter failure in multivariable analyses. We did not find an association between vancomycin infusion and catheter failure in multivariable analyses.
Authors
- Peter Juhl‐Olsen (ORCID: https://orcid.org/0000-0003-1951-9091)
- Cecilie Dahl Baltsen
- Julie Krath
- Jesper Fredskilde
- Ryan Offersen
- Simone Krogh Christensen
- Kamilla Valentin
Institutions
- Aarhus University (DK)
- Aarhus University Hospital (DK)
Publication Details
- Journal
- Acta Anaesthesiologica Scandinavica
- Published
- 2024-08-26
- DOI
- https://doi.org/10.1111/aas.14517
- Citations
- 1
- Primary Topic
- Central Venous Catheters and Hemodialysis
- Type
- article
- Field-Weighted Citation Impact
- 0.74