Design and Analysis of a Contact Piezo Microphone for Recording Tracheal Breathing Sounds

Analysis of tracheal breathing sounds (TBS) is a significant area of study in medical diagnostics and monitoring for respiratory diseases and obstructive sleep apnea (OSA). Recorded at the suprasternal notch, TBS can provide detailed insights into the respiratory system's functioning and health. This method has been particularly useful for non-invasive assessments and is used in various clinical settings, such as OSA, asthma, respiratory infectious diseases, lung function, and detection during either wakefulness or sleep. One of the challenges and limitations of TBS recording is the background noise, including speech sound, movement, and even non-tracheal breathing sounds propagating in the air. The breathing sounds captured from the nose or mouth can interfere with the tracheal breathing sounds, making it difficult to isolate the sounds necessary for accurate diagnostics. In this study, two surface microphones are proposed to accurately record TBS acquired solely from the trachea. The frequency response of each microphone is compared with a reference microphone. Additionally, this study evaluates the tracheal and lung breathing sounds of six participants recorded using the proposed microphones versus a commercial omnidirectional microphone, both in environments with and without background white noise. The proposed microphones demonstrated reduced susceptibility to background noise particularly in the frequency ranges (1800-2199) Hz and (2200-2599) Hz with maximum deviation of 2 dB and 2.1 dB, respectively, compared to 9 dB observed in the commercial microphone. The findings of this study have potential implications for improving the accuracy and reliability of respiratory diagnostics in clinical practice.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-26
DOI
https://doi.org/10.3390/s24175511
Citations
5
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of a Contact Piezo Microphone for Recording Tracheal Breathing Sounds

Zahra Moussavi, Walid Ashraf
5 citations
Sensors
Phonocardiography and Auscultation Techniques
2.09
article

Design and Analysis of a Contact Piezo Microphone for Recording Tracheal Breathing Sounds

Zahra Moussavi, Walid Ashraf
article en
5 citations

Abstract

Analysis of tracheal breathing sounds (TBS) is a significant area of study in medical diagnostics and monitoring for respiratory diseases and obstructive sleep apnea (OSA). Recorded at the suprasternal notch, TBS can provide detailed insights into the respiratory system's functioning and health. This method has been particularly useful for non-invasive assessments and is used in various clinical settings, such as OSA, asthma, respiratory infectious diseases, lung function, and detection during either wakefulness or sleep. One of the challenges and limitations of TBS recording is the background noise, including speech sound, movement, and even non-tracheal breathing sounds propagating in the air. The breathing sounds captured from the nose or mouth can interfere with the tracheal breathing sounds, making it difficult to isolate the sounds necessary for accurate diagnostics. In this study, two surface microphones are proposed to accurately record TBS acquired solely from the trachea. The frequency response of each microphone is compared with a reference microphone. Additionally, this study evaluates the tracheal and lung breathing sounds of six participants recorded using the proposed microphones versus a commercial omnidirectional microphone, both in environments with and without background white noise. The proposed microphones demonstrated reduced susceptibility to background noise particularly in the frequency ranges (1800-2199) Hz and (2200-2599) Hz with maximum deviation of 2 dB and 2.1 dB, respectively, compared to 9 dB observed in the commercial microphone. The findings of this study have potential implications for improving the accuracy and reliability of respiratory diagnostics in clinical practice.

SensorsVol. 24(17)
University of Manitoba (CA)
Canadian Institutes of Health Research
Good health and well-being
Openalex Percentile: Top 12%
Phonocardiography and Auscultation Techniques
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.