An improved design of high-signal-to-noise ratio spiral-coil EMAT for high-temperature defect detection
The study introduces an enhanced concentric spiral-coil EMAT to tackle low signal-to-noise ratio (SNR) in high-temperature carbon steel forging defect detection. With a non-overlapping concentric coil design, simulations and experiments were conducted, utilizing a finite element model with circuit-field coupling to optimize parameters. Results show the improved EMAT enhances SNR by up to 20.96 dB compared to traditional designs. High-temperature tests demonstrate its capability to detect Ф5 mm holes at 650℃, with SNR increasing by 11.24 dB as temperature rises from 100℃ to 500℃, validating the optimization method's effectiveness.
Authors
- Yuan Liu (ORCID: https://orcid.org/0000-0002-6841-7078)
- Fasheng Qiu (ORCID: https://orcid.org/0000-0002-6771-8688)
- Bo Hu (ORCID: https://orcid.org/0000-0002-4234-099X)
- Wenze Shi
- Chao Lu (ORCID: https://orcid.org/0000-0002-4939-9759)
- Yuxuan Zou
Institutions
- Nanchang Hangkong University (CN)
Publication Details
- Journal
- Nondestructive Testing And Evaluation
- Published
- 2024-08-25
- DOI
- https://doi.org/10.1080/10589759.2024.2389953
- Citations
- 11
- Primary Topic
- Ultrasonics and Acoustic Wave Propagation
- Type
- article
- Field-Weighted Citation Impact
- 2.96
Funders
- National Natural Science Foundation of China