Optical clearing: an alternative sample preparation method for propagation based phase contrast μCT

Synchrotron radiation propagation-based phase-contrast micro-computed tomography (SR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m2"><mml:mi mathvariant="normal">μ</mml:mi></mml:math> CT) has been used increasingly for detailed characterization of tissue specimens, alternative to classical histology. It allows rapid and non-destructive three-dimensional (3D) virtual histology of unstained specimens. Although many studies show that standard protocols for formalin-fixation and paraffin-embedded (FFPE) tissue specimens are well suited for propagation based phase-contrast imaging (PBI), refinement of sample preparation protocols for this relatively recent development is still in its early stage. There are several limitations using FFPE blocks including air-bubble inclusion, and crack formation, which affect the quality of the micro-CT scans. In this study we demonstrate that optical clearing of colon cancer specimen followed by embedding in Phytagel, as an alternative sample preparation protocol yields comparable PBI micro-CT image quality and mitigates the aforementioned drawbacks of FFPE specimens. Moreover, since single-distance phase retrieval algorithms for PBI image reconstruction expect scanned materials to be either weakly-absorbing or having a fixed ratio between absorption and phase shift, we hypothesize that optical clearing will result in specimens that are well in line with these mathematical assumption of the applied phase retrieval algorithm (homogeneous form of the Transport-of-Intensity equation TIE-HOM). In addition, we show that classical histological analysis is still possible after re-embedding of the specimen in paraffin. Thus, the proposed novel workflow to scan optical cleared specimens using SR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m3"><mml:mi mathvariant="normal">μ</mml:mi></mml:math> CT can be used in combination with light sheet microscopy and can be integrated in a classical pipeline for pathological tissue characterization.

Authors

Institutions

Publication Details

Journal
Frontiers in Physics
Published
2024-08-26
DOI
https://doi.org/10.3389/fphy.2024.1433895
Citations
4
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
2.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical clearing: an alternative sample preparation method for propagation based phase contrast μCT

Lorenzo D’Amico, Angelika Svetlove, Hanibal Bohnenberger, Frauke Alves et al.
4 citations
Frontiers in Physics
Advanced X-ray Imaging Techniques
2.43
article

Optical clearing: an alternative sample preparation method for propagation based phase contrast μCT

Lorenzo D’Amico, Angelika Svetlove, Hanibal Bohnenberger, Frauke Alves, Jeannine Missbach‐Guentner, Christian Dullin, Elena Longo, Diana Pinkert‐Leetsch, Giuliana Tromba, Md Motiur Rahman Sagar
article en
4 citations

Abstract

Synchrotron radiation propagation-based phase-contrast micro-computed tomography (SR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m2"><mml:mi mathvariant="normal">μ</mml:mi></mml:math> CT) has been used increasingly for detailed characterization of tissue specimens, alternative to classical histology. It allows rapid and non-destructive three-dimensional (3D) virtual histology of unstained specimens. Although many studies show that standard protocols for formalin-fixation and paraffin-embedded (FFPE) tissue specimens are well suited for propagation based phase-contrast imaging (PBI), refinement of sample preparation protocols for this relatively recent development is still in its early stage. There are several limitations using FFPE blocks including air-bubble inclusion, and crack formation, which affect the quality of the micro-CT scans. In this study we demonstrate that optical clearing of colon cancer specimen followed by embedding in Phytagel, as an alternative sample preparation protocol yields comparable PBI micro-CT image quality and mitigates the aforementioned drawbacks of FFPE specimens. Moreover, since single-distance phase retrieval algorithms for PBI image reconstruction expect scanned materials to be either weakly-absorbing or having a fixed ratio between absorption and phase shift, we hypothesize that optical clearing will result in specimens that are well in line with these mathematical assumption of the applied phase retrieval algorithm (homogeneous form of the Transport-of-Intensity equation TIE-HOM). In addition, we show that classical histological analysis is still possible after re-embedding of the specimen in paraffin. Thus, the proposed novel workflow to scan optical cleared specimens using SR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="m3"><mml:mi mathvariant="normal">μ</mml:mi></mml:math> CT can be used in combination with light sheet microscopy and can be integrated in a classical pipeline for pathological tissue characterization.

Frontiers in PhysicsVol. 12
University of Trieste (IT), Heidelberg University (DE), University Hospital Heidelberg (DE), Elettra-Sincrotrone Trieste S.C.p.A. (IT)
Niedersächsisches Ministerium für Wissenschaft und Kultur
Openalex Percentile: Top 12%
Advanced X-ray Imaging Techniques
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.