Comparison of directly and indirectly estimated entrance skin dose (ESD) for diagnostic radiation qualities (RQR, RQA and RQT) using water phantom and shadowfree diagnostic chamber (SFD)

Abstract Background The aim of this study was to find the entrance skin dose (ESD) for diagnostic radiation qualities RQRs, RQAs and RQTs given in IAEA technical report series No. 457 using direct and indirect methods of measurement. Measurements were done for 5 × 5, 10 × 10, 15 × 15, 20 × 20 and 25 × 25 cm 2 field sizes and 70, 80, 90 and 100 cm source to surface distance (SSD) using shadow-free diagnostic (SFD) chamber and water phantom having dimension 30 × 30 × 30 cm 3 . ESD direct measurements were done by placing SFD chamber on the surface of water phantom, while in the case of indirect measurements, air kerma values were obtained. Results ESD values for different selected radiation qualities RQR2, RQR5, RQR8, RQR10, RQA2, RQA5, RQA8, RQA10, RQT8, RQT9 and RQT10 were found to be in the range of 0.0045–5.11 mGy per examination. Conclusions Results obtained were found to be comparable with ESD values published in the literature. The obtained results in this research would help in establishing the national diagnostic reference levels (DRLs) which would help in the optimization of diagnostic imaging procedures. It would also help the radiographers to optimize field sizes and SSDs in order to reduce dose to the patients thereby ensuring good radiological practices, and this would reduce the stochastic risk to the patients caused by the ionizing radiations.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2024-08-26
DOI
https://doi.org/10.1186/s43055-024-01337-5
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of directly and indirectly estimated entrance skin dose (ESD) for diagnostic radiation qualities (RQR, RQA and RQT) using water phantom and shadowfree diagnostic chamber (SFD)

Wajeeha Shaheen, Umar Hussain Haider, Babar Hussain, Shakeel Ur Rehman
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
article

Comparison of directly and indirectly estimated entrance skin dose (ESD) for diagnostic radiation qualities (RQR, RQA and RQT) using water phantom and shadowfree diagnostic chamber (SFD)

Wajeeha Shaheen, Umar Hussain Haider, Babar Hussain, Shakeel Ur Rehman
article en

Abstract

Abstract Background The aim of this study was to find the entrance skin dose (ESD) for diagnostic radiation qualities RQRs, RQAs and RQTs given in IAEA technical report series No. 457 using direct and indirect methods of measurement. Measurements were done for 5 × 5, 10 × 10, 15 × 15, 20 × 20 and 25 × 25 cm 2 field sizes and 70, 80, 90 and 100 cm source to surface distance (SSD) using shadow-free diagnostic (SFD) chamber and water phantom having dimension 30 × 30 × 30 cm 3 . ESD direct measurements were done by placing SFD chamber on the surface of water phantom, while in the case of indirect measurements, air kerma values were obtained. Results ESD values for different selected radiation qualities RQR2, RQR5, RQR8, RQR10, RQA2, RQA5, RQA8, RQA10, RQT8, RQT9 and RQT10 were found to be in the range of 0.0045–5.11 mGy per examination. Conclusions Results obtained were found to be comparable with ESD values published in the literature. The obtained results in this research would help in establishing the national diagnostic reference levels (DRLs) which would help in the optimization of diagnostic imaging procedures. It would also help the radiographers to optimize field sizes and SSDs in order to reduce dose to the patients thereby ensuring good radiological practices, and this would reduce the stochastic risk to the patients caused by the ionizing radiations.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 55(1)
Pakistan Institute of Engineering and Applied Sciences (PK), Pakistan Institute of Nuclear Science and Technology (PK)
Pakistan Institute of Engineering and Applied Sciences
Clean water and sanitation
Openalex Percentile: Top 77%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.