Collision cross‐section measurements of small molecules via transient decay profiles observed in Orbitrap mass analyzers

Collision cross section (CCS) of organic compounds can be measured via Fourier transform-based mass spectrometry (MS) by modeling the decay rate of transient signals in the analyzer. Deriving CCS values of low-mass molecules (mass < 2000 Da and CCS < 500 Å<sup>2</sup>) with Orbitrap MS is challenging due to their high axial frequencies and small absolute variances in cross-sectional profiles. Here, we acquired mass spectra of progressively more complex low-mass analytes using commercial Orbitrap mass spectrometers. The transient signals were processed using Fast Fourier transform (FFT) and short-time Fourier transform (StFFT) to derive decay constants of multiple select ionic species from a single MS full-scan experiment. Decay constants were translated into CCS values using at least two internal standards in the same mass spectrum. Our results suggest target ionic species should have high S/N in order to derive CCS values with ≤0.5% uncertainty. Limitations in the precision of CCS measurements reflect local space charge effects that disturb ion motion in the analyzer. The derived CCS values of polymer like fragments of Ultramark 1621 and small molecules such as individual protonated amino acids can achieve average ±1% error with selection of internal standards across a wide mass range. Future studies need to optimize the strategy to select internal standards in order to improve the precision and accuracy of CCS measurements for small molecules via Orbitrap MS.

Authors

Institutions

Publication Details

Journal
Rapid Communications in Mass Spectrometry
Published
2024-08-26
DOI
https://doi.org/10.1002/rcm.9887
Citations
5
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.20

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Collision cross‐section measurements of small molecules via transient decay profiles observed in Orbitrap mass analyzers

Ricardo Arévalo, Ziqin Ni
5 citations
Rapid Communications in Mass Spectrometry
Mass Spectrometry Techniques and Applications
1.20
article

Collision cross‐section measurements of small molecules via transient decay profiles observed in Orbitrap mass analyzers

Ricardo Arévalo, Ziqin Ni
article en
5 citations

Abstract

Collision cross section (CCS) of organic compounds can be measured via Fourier transform-based mass spectrometry (MS) by modeling the decay rate of transient signals in the analyzer. Deriving CCS values of low-mass molecules (mass < 2000 Da and CCS < 500 Å<sup>2</sup>) with Orbitrap MS is challenging due to their high axial frequencies and small absolute variances in cross-sectional profiles. Here, we acquired mass spectra of progressively more complex low-mass analytes using commercial Orbitrap mass spectrometers. The transient signals were processed using Fast Fourier transform (FFT) and short-time Fourier transform (StFFT) to derive decay constants of multiple select ionic species from a single MS full-scan experiment. Decay constants were translated into CCS values using at least two internal standards in the same mass spectrum. Our results suggest target ionic species should have high S/N in order to derive CCS values with ≤0.5% uncertainty. Limitations in the precision of CCS measurements reflect local space charge effects that disturb ion motion in the analyzer. The derived CCS values of polymer like fragments of Ultramark 1621 and small molecules such as individual protonated amino acids can achieve average ±1% error with selection of internal standards across a wide mass range. Future studies need to optimize the strategy to select internal standards in order to improve the precision and accuracy of CCS measurements for small molecules via Orbitrap MS.

Rapid Communications in Mass SpectrometryVol. 38(20)
University of Maryland, College Park (US)
National Aeronautics and Space Administration, Nuclear Safety and Security Commission
Openalex Percentile: Top 24%
Mass Spectrometry Techniques and Applications
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Collision cross‐section measurements of small molecules via transient decay profiles observed in Orbitrap mass analyzers — Ricardo Arévalo, Ziqin Ni · Rapid Communications in Mass Spectrometry (2024) | TGRS Research Map | TGRS