Speed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown

Abstract Advanced adiabatic compressed air energy storage (AA-CAES) starts and shuts down frequently. The default operation of the high-pressure compressor (HP) connected to the cavern is to reduce the speed of the inverter motor during shutdown. Whether or not the default speed strategy is safe has yet to be focused on. To this end, a detailed charging process comprising three series of centrifugal compressors with intercoolers was constructed within the framework of unisimdesign. The safety measures were meticulously considered by integrating antisurge circuits, vent valves, and check valves. Proportional–integral (PI) controllers were allocated to the primary component to govern the shutdown procedure. The speed strategy of the HP inverter motor during the load shedding stage is the focus of research. Six speed strategies, including decreasing speed, constant speed, and increasing speed, were discussed, respectively. The discussion focused on changes made to air injection, inlet mass flow of the HP, inlet and outlet pressure of both the middle-pressure compressor (MP) and HP, and energy efficiency. The study found that implementing the minimum allowable speed for the inverter motor speed (IMS) and increasing speed during the load shedding stage can cause fluctuations in the air injection. As IMS increases at the end of the load shedding stage, the pressure anomalies at the MP outlet and the HP inlet weaken, and the shutdown process's energy efficiency improves. The HP inlet flow fluctuations caused by various strategies were within an acceptable range. This study reveals that there is a mutual influence between components in the charging process of AA-CAES. An appropriate speed strategy for the HP inverter motor can mitigate the operational hazards. The results of this study can provide guidance for similar AA-CAES shutdowns.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2024-08-26
DOI
https://doi.org/10.1115/1.4066358
Citations
2
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Speed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown

Cheng Jia, Qin Cui, Guoliang Qin, Yi Wang
2 citations
Journal of Engineering for Gas Turbines and Power
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
article

Speed Strategy on High-Pressure Compressor for the Charging Process of Advanced Adiabatic Compressed Air Energy Storage During Dynamic Shutdown

Cheng Jia, Qin Cui, Guoliang Qin, Yi Wang
article en
2 citations

Abstract

Abstract Advanced adiabatic compressed air energy storage (AA-CAES) starts and shuts down frequently. The default operation of the high-pressure compressor (HP) connected to the cavern is to reduce the speed of the inverter motor during shutdown. Whether or not the default speed strategy is safe has yet to be focused on. To this end, a detailed charging process comprising three series of centrifugal compressors with intercoolers was constructed within the framework of unisimdesign. The safety measures were meticulously considered by integrating antisurge circuits, vent valves, and check valves. Proportional–integral (PI) controllers were allocated to the primary component to govern the shutdown procedure. The speed strategy of the HP inverter motor during the load shedding stage is the focus of research. Six speed strategies, including decreasing speed, constant speed, and increasing speed, were discussed, respectively. The discussion focused on changes made to air injection, inlet mass flow of the HP, inlet and outlet pressure of both the middle-pressure compressor (MP) and HP, and energy efficiency. The study found that implementing the minimum allowable speed for the inverter motor speed (IMS) and increasing speed during the load shedding stage can cause fluctuations in the air injection. As IMS increases at the end of the load shedding stage, the pressure anomalies at the MP outlet and the HP inlet weaken, and the shutdown process's energy efficiency improves. The HP inlet flow fluctuations caused by various strategies were within an acceptable range. This study reveals that there is a mutual influence between components in the charging process of AA-CAES. An appropriate speed strategy for the HP inverter motor can mitigate the operational hazards. The results of this study can provide guidance for similar AA-CAES shutdowns.

Journal of Engineering for Gas Turbines and PowerVol. 147(1)
Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 43%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.