Comparative analysis of the efficiency of the Broken Tool Remover-Pen versus Zumax kit in the removal of fractured NiTi files from the root canal system. An in vitro study

Abstract Introduction: Removal of a broken instrument may result in excessive dentin destruction and eventual tooth extraction. Therefore, the aim of this study is to evaluate the success of the Broken Tool Remover (BTR)-Pen system versus the Zumax kit in the retrieval of separated rotary files from the root canals, root canal volume changes, and retrieval time. Materials and Methods: Forty mandibular first molars were used in this investigation. Mesiobuccal canals were instrumented by ProTaper Next Rotary System up to a standard apical size 20/40 taper. Five mm of X2 file size 25/60 taper was fractured at a level of 3 mm apical to canal orifice. Teeth were randomly divided into two groups, 20 samples each. In Group A, fractured instruments were retrieved by utilizing BTR-Pen. In Group B, fractured files were retrieved using a Zumax kit. The success rate (%), as well as the postretrieval volumetric canal changes (mm 3 ) using cone-beam computed tomography, and the retrieval time (min) were calculated in both groups. Results: The success rate of the separated fragment retrieval in Groups A and B was 80% and 90%, respectively, with no significant difference ( P = 0.31). Moreover, concerning canal volume changes, there was a significant difference ( P = 0:001) in comparison between the pre- and postretrieval volume changes in both groups. Group A showed significant lower changes ( P = 0.0051) in root canal volume than Group B. Furthermore, the mean time ± standard deviation of retrieval in Group A was 29.56 ± 4.09 min, whereas in Group B, it was 23.29 ± 7.15 min with a significant difference ( P = 0.00) between the two groups. Conclusion: Both devices were efficient and successful in retrieving separated rotary files. The utilization of the Zumax kit resulted in greater dentin loss but faster regarding time of retrieval.

Authors

Institutions

Publication Details

Journal
Saudi Endodontic Journal
Published
2024-08-26
DOI
https://doi.org/10.4103/sej.sej_33_24
Citations
3
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
1.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of the efficiency of the Broken Tool Remover-Pen versus Zumax kit in the removal of fractured NiTi files from the root canal system. An in vitro study

Farah T. Baraktat, Mohamed I. Attia, A. Yousef Saad
3 citations
Saudi Endodontic Journal
Endodontics and Root Canal Treatments
1.48
article

Comparative analysis of the efficiency of the Broken Tool Remover-Pen versus Zumax kit in the removal of fractured NiTi files from the root canal system. An in vitro study

Farah T. Baraktat, Mohamed I. Attia, A. Yousef Saad
article en
3 citations

Abstract

Abstract Introduction: Removal of a broken instrument may result in excessive dentin destruction and eventual tooth extraction. Therefore, the aim of this study is to evaluate the success of the Broken Tool Remover (BTR)-Pen system versus the Zumax kit in the retrieval of separated rotary files from the root canals, root canal volume changes, and retrieval time. Materials and Methods: Forty mandibular first molars were used in this investigation. Mesiobuccal canals were instrumented by ProTaper Next Rotary System up to a standard apical size 20/40 taper. Five mm of X2 file size 25/60 taper was fractured at a level of 3 mm apical to canal orifice. Teeth were randomly divided into two groups, 20 samples each. In Group A, fractured instruments were retrieved by utilizing BTR-Pen. In Group B, fractured files were retrieved using a Zumax kit. The success rate (%), as well as the postretrieval volumetric canal changes (mm 3 ) using cone-beam computed tomography, and the retrieval time (min) were calculated in both groups. Results: The success rate of the separated fragment retrieval in Groups A and B was 80% and 90%, respectively, with no significant difference ( P = 0.31). Moreover, concerning canal volume changes, there was a significant difference ( P = 0:001) in comparison between the pre- and postretrieval volume changes in both groups. Group A showed significant lower changes ( P = 0.0051) in root canal volume than Group B. Furthermore, the mean time ± standard deviation of retrieval in Group A was 29.56 ± 4.09 min, whereas in Group B, it was 23.29 ± 7.15 min with a significant difference ( P = 0.00) between the two groups. Conclusion: Both devices were efficient and successful in retrieving separated rotary files. The utilization of the Zumax kit resulted in greater dentin loss but faster regarding time of retrieval.

Saudi Endodontic JournalVol. 14(3)
Pharos University in Alexandria (EG)
Openalex Percentile: Top 19%
Endodontics and Root Canal Treatments
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative analysis of the efficiency of the Broken Tool Remover-Pen versus Zumax kit in the removal of fractured NiTi files from the root canal system. An in vitro study — Farah T. Baraktat, Mohamed I. Attia, et al. · Saudi Endodontic Journal (2024) | TGRS Research Map | TGRS