A Keyphasor-Free Traveling Waves Analysis Method Based on Blade Tip Timing and Experimental Validation

Abstract Vibration-induced high-cycle fatigue of blades is a prevalent issue in turbomachinery. Blade tip timing (BTT) emerges as a nonintrusive, promising method for assessing blade vibration. Despite its potential, BTT's inherent measurement limitations often result in the undersampling of individual blade data. Assuming that the bladed-disk assembly vibrates in nodal diameter modes, traveling wave analysis (TWA) can overcome the limitations of undersampling and identify the nodal diameter modes associated with the frequency components. Traditional TWA methods rely on a keyphasor or once-per-revolution sensor to provide accurate reference signals. However, such a sensor could be damaged during operation or challenging to install due to limited space in field tests. In this paper, a new keyphasor-free TWA (KF-TWA) method is introduced, which is capable of measuring the order and nodal diameter of nodal diameter vibrations with as few as two sensors. Theoretical derivations reveal the method's resilience to the steady-state displacement of blades. The feasibility and effectiveness of the KF-TWA method are validated through numerical experiments and compressor tests. In the numerical experiments, blade detuning and nodal diameter vibration responses are simulated, leading to the development of a criterion for identifying nodal diameter vibrations. A compressor test rig, equipped with a 64-keyphasor disk and a sufficient number of circumferentially distributed sensors, is designed to provide blade vibration benchmark. In the experiments, the KF-TWA method successfully identified nodal diameter vibrations with amplitudes as low as 0.014 mm, consistently yielding identical results across multiple sensor pairs, which demonstrates a higher robustness compared to the traditional TWA method. The results presented offer valuable insights into the engineering application of this technology.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2024-08-26
DOI
https://doi.org/10.1115/1.4066351
Citations
1
Primary Topic
Bladed Disk Vibration Dynamics
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Keyphasor-Free Traveling Waves Analysis Method Based on Blade Tip Timing and Experimental Validation

Zhicheng Xiao, Xiaocheng Zhu, Yiming Meng, Shang Wang et al.
1 citations
Journal of Engineering for Gas Turbines and Power
Bladed Disk Vibration Dynamics
0.26
article

A Keyphasor-Free Traveling Waves Analysis Method Based on Blade Tip Timing and Experimental Validation

Zhicheng Xiao, Xiaocheng Zhu, Yiming Meng, Shang Wang, Hua Ouyang, Pengfei Chai
article en
1 citations

Abstract

Abstract Vibration-induced high-cycle fatigue of blades is a prevalent issue in turbomachinery. Blade tip timing (BTT) emerges as a nonintrusive, promising method for assessing blade vibration. Despite its potential, BTT's inherent measurement limitations often result in the undersampling of individual blade data. Assuming that the bladed-disk assembly vibrates in nodal diameter modes, traveling wave analysis (TWA) can overcome the limitations of undersampling and identify the nodal diameter modes associated with the frequency components. Traditional TWA methods rely on a keyphasor or once-per-revolution sensor to provide accurate reference signals. However, such a sensor could be damaged during operation or challenging to install due to limited space in field tests. In this paper, a new keyphasor-free TWA (KF-TWA) method is introduced, which is capable of measuring the order and nodal diameter of nodal diameter vibrations with as few as two sensors. Theoretical derivations reveal the method's resilience to the steady-state displacement of blades. The feasibility and effectiveness of the KF-TWA method are validated through numerical experiments and compressor tests. In the numerical experiments, blade detuning and nodal diameter vibration responses are simulated, leading to the development of a criterion for identifying nodal diameter vibrations. A compressor test rig, equipped with a 64-keyphasor disk and a sufficient number of circumferentially distributed sensors, is designed to provide blade vibration benchmark. In the experiments, the KF-TWA method successfully identified nodal diameter vibrations with amplitudes as low as 0.014 mm, consistently yielding identical results across multiple sensor pairs, which demonstrates a higher robustness compared to the traditional TWA method. The results presented offer valuable insights into the engineering application of this technology.

Journal of Engineering for Gas Turbines and PowerVol. 147(2)
Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Bladed Disk Vibration Dynamics
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.