Effect of electromagnetic radiation from cell phone on working length determination by electronic apex locator: An in vivo study

Abstract Introduction: Technical support manuals of certain electronic apex locators (EALs) have stated that electromagnetic radiation could lead to abnormal functioning of the EALs. Even so, in a dental clinic, patients often keep their cell phones on and nearby while undergoing root canal treatment. The purpose of this study was to evaluate the effect of electromagnetic radiation from cell phone on working length determination by latest generation EAL. Materials and Methods: Thirty patients in need of root canal therapy for incisors, canines or premolars with one canal, and completely formed apices were selected. Determination of working length was carried out using a K-file with 5 th generation apex locator (AirPex, Eighteeth). A standard cell phone device (Samsung M51) was used to evaluate the effect of electromagnetic radiation on the determination of working length. Working length was measured under the following clinical settings: no cell phone within the working area; cell phone within two feet from the EAL in standby mode and cell phone within two feet from the EAL in the active mode (Activated Bluetooth, Wi-Fi and Ringing Mode). Statistical Analysis: One-way analysis of variance test was used to compare three clinical settings. P value was set at 0.05. Results: The findings revealed no significant difference between the working length determinations among the three clinical settings of the study ( P > 0.05). Conclusion: According to this study, using cell phones (in standby or active mode) in the vicinity of EAL does not have a significant effect on working length determination.

Authors

Publication Details

Journal
Saudi Endodontic Journal
Published
2024-08-26
DOI
https://doi.org/10.4103/sej.sej_22_24
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of electromagnetic radiation from cell phone on working length determination by electronic apex locator: An in vivo study

Kiran Keswani, Vinod Kambli, Shraddha Padwal, Vishwajit Lokhande et al.
Saudi Endodontic Journal
Endodontics and Root Canal Treatments
article

Effect of electromagnetic radiation from cell phone on working length determination by electronic apex locator: An in vivo study

Kiran Keswani, Vinod Kambli, Shraddha Padwal, Vishwajit Lokhande, Manjiri Raje, P. S. Shetty
article en

Abstract

Abstract Introduction: Technical support manuals of certain electronic apex locators (EALs) have stated that electromagnetic radiation could lead to abnormal functioning of the EALs. Even so, in a dental clinic, patients often keep their cell phones on and nearby while undergoing root canal treatment. The purpose of this study was to evaluate the effect of electromagnetic radiation from cell phone on working length determination by latest generation EAL. Materials and Methods: Thirty patients in need of root canal therapy for incisors, canines or premolars with one canal, and completely formed apices were selected. Determination of working length was carried out using a K-file with 5 th generation apex locator (AirPex, Eighteeth). A standard cell phone device (Samsung M51) was used to evaluate the effect of electromagnetic radiation on the determination of working length. Working length was measured under the following clinical settings: no cell phone within the working area; cell phone within two feet from the EAL in standby mode and cell phone within two feet from the EAL in the active mode (Activated Bluetooth, Wi-Fi and Ringing Mode). Statistical Analysis: One-way analysis of variance test was used to compare three clinical settings. P value was set at 0.05. Results: The findings revealed no significant difference between the working length determinations among the three clinical settings of the study ( P > 0.05). Conclusion: According to this study, using cell phones (in standby or active mode) in the vicinity of EAL does not have a significant effect on working length determination.

Saudi Endodontic JournalVol. 14(3)
Openalex Percentile: Top 80%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of electromagnetic radiation from cell phone on working length determination by electronic apex locator: An in vivo study — Kiran Keswani, Vinod Kambli, et al. · Saudi Endodontic Journal (2024) | TGRS Research Map | TGRS