The use of modified nickel–titanium rotary file for preparing staging platform to retrieve instrument fragments from narrow and curved canal

Abstract Staging platform (SP) uses a modified Gates Glidden (GG) to help retrieve separated instruments deep in the root canal. However, GG drills may cause damage or severe dentin loss. A 46-year-old male patient was referred to the endodontic postgraduate clinics complaining of pain on biting related to the mandibular right second molar (#47). The preoperative periapical radiograph of #47 showed a previously initiated root canal treatment with an approximately 8-mm separated instrument in the apical third of a curved mesiolingual canal. A nickel–titanium (NiTi) rotary file size 25/0.04 was flattened with a carbide bur. The modified file was then used to create a centered SP. After SP was achieved, an ultrasonic tip was used at lower power for the trephination of dentin. The fragment became loose, and retrieval was achieved. The use of a modified NiTi rotary file presented a safe and alternative option to establish SP for instrument retrieval instead of using GG drills.

Authors

Institutions

Publication Details

Journal
Saudi Endodontic Journal
Published
2024-08-26
DOI
https://doi.org/10.4103/sej.sej_223_23
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The use of modified nickel–titanium rotary file for preparing staging platform to retrieve instrument fragments from narrow and curved canal

Laila Bahammam, Abdulrhman Ateq Alhwieti
Saudi Endodontic Journal
Endodontics and Root Canal Treatments
article

The use of modified nickel–titanium rotary file for preparing staging platform to retrieve instrument fragments from narrow and curved canal

Laila Bahammam, Abdulrhman Ateq Alhwieti
article en

Abstract

Abstract Staging platform (SP) uses a modified Gates Glidden (GG) to help retrieve separated instruments deep in the root canal. However, GG drills may cause damage or severe dentin loss. A 46-year-old male patient was referred to the endodontic postgraduate clinics complaining of pain on biting related to the mandibular right second molar (#47). The preoperative periapical radiograph of #47 showed a previously initiated root canal treatment with an approximately 8-mm separated instrument in the apical third of a curved mesiolingual canal. A nickel–titanium (NiTi) rotary file size 25/0.04 was flattened with a carbide bur. The modified file was then used to create a centered SP. After SP was achieved, an ultrasonic tip was used at lower power for the trephination of dentin. The fragment became loose, and retrieval was achieved. The use of a modified NiTi rotary file presented a safe and alternative option to establish SP for instrument retrieval instead of using GG drills.

Saudi Endodontic JournalVol. 14(3)
King Abdulaziz University (SA), Armed Forces Hospital (SA)
Life below water
Openalex Percentile: Top 80%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.