Information limit of 15 picometers achieved with bright-field ptychography

It is generally assumed that a high spatial resolution of a microscope requires a large numerical aperture of the imaging lens or detector. In this study, the information limit of 15 pm is achieved in transmission electron microscopy using only the bright-field disk (small numerical aperture) via multislice ptychography. The results indicate that high-frequency information has been encoded in the bright-field disk due to the multiple scattering of electrons in the objects, making it possible to break the diffraction limit of imaging via bright-field ptychography.

Authors

Institutions

Publication Details

Journal
Physical review. B./Physical review. B
Published
2024-08-26
DOI
https://doi.org/10.1103/physrevb.110.l060104
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Information limit of 15 picometers achieved with bright-field ptychography

Haozhi Sha, Jizhe Cui, Rong Yu, Wenfeng Yang
Physical review. B./Physical review. B
Advanced X-ray Imaging Techniques
article

Information limit of 15 picometers achieved with bright-field ptychography

Haozhi Sha, Jizhe Cui, Rong Yu, Wenfeng Yang
article en

Abstract

It is generally assumed that a high spatial resolution of a microscope requires a large numerical aperture of the imaging lens or detector. In this study, the information limit of 15 pm is achieved in transmission electron microscopy using only the bright-field disk (small numerical aperture) via multislice ptychography. The results indicate that high-frequency information has been encoded in the bright-field disk due to the multiple scattering of electrons in the objects, making it possible to break the diffraction limit of imaging via bright-field ptychography.

Physical review. B./Physical review. BVol. 110(6)
Tsinghua University (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 86%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Information limit of 15 picometers achieved with bright-field ptychography — Haozhi Sha, Jizhe Cui, et al. · Physical review. B./Physical review. B (2024) | TGRS Research Map | TGRS