Distribution and associated factors of keratometry and corneal astigmatism in an elderly population

To determine the distribution of keratometry and corneal astigmatism (CA) and their association with demographic factors, systemic parameters, anthropometric measures, ocular biometric indices, and refractive errors in people aged 60 years and above. In this cross-sectional study, 160 clusters were randomly selected from Tehran city (Iran) using the multi-stage cluster sampling method. All participants underwent optometric examinations including testing uncorrected and best-corrected distance visual acuity, non-cycloplegic autorefraction, and subjective refraction. Pentacam imaging for all participants was carried out using Pentacam AXL. Keratometry and CA were reported based on Pentacam's data. The average, standard deviation (SD) and 95% confidence interval (CI) of flat keratometry (Kf), steep keratometry (Ks), mean keratometry (mean K), and CA were 44.02 ± 1.58 D (95% CI 43.94-44.1), 44.86 ± 1.67 D (95% CI 44.78-44.94), 44.44 ± 1.58 D (95% CI 44.36-44.52), and 0.84 ± 0.74 D (95% CI 0.81-0.87), respectively. The 95% and 99% percentiles of mean K were 47.1 and 48.6 D, respectively. According to the multiple generalized estimating equation model, the mean K was significantly higher in males, in myopes, and in those with higher systolic blood pressure. Moreover, the mean K was inversely related to the axial length, height, anterior chamber depth (ACD), corneal diameter, and central corneal thickness (CCT). The prevalence of various types of CA based on a cut-off > 0.50 D was as follows; with-the-rule: 32.5% (95% CI 30.6-34.4), against-the-rule: 18.2% (95% CI 16.7-19.7), and oblique: 10.0% (95% CI 9.1-11.0). The present study investigated the normal distribution of keratometry and CA in individuals ≥ 60 years, and results can be used in clinical matters, especially in intraocular lens power calculation. Sex, systolic blood pressure, height, and some biometric components such as ACD, corneal diameter, and CCT were significantly related to keratometry and should be considered.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-26
DOI
https://doi.org/10.1038/s41598-024-70850-4
Citations
3
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distribution and associated factors of keratometry and corneal astigmatism in an elderly population

Hassan Hashemi, Mohamadreza Aghamirsalim, Mehdi Khabazkhoob, Alireza Hashemi
3 citations
Scientific Reports
Corneal surgery and disorders
1.21
article

Distribution and associated factors of keratometry and corneal astigmatism in an elderly population

Hassan Hashemi, Mohamadreza Aghamirsalim, Mehdi Khabazkhoob, Alireza Hashemi
article en
3 citations

Abstract

To determine the distribution of keratometry and corneal astigmatism (CA) and their association with demographic factors, systemic parameters, anthropometric measures, ocular biometric indices, and refractive errors in people aged 60 years and above. In this cross-sectional study, 160 clusters were randomly selected from Tehran city (Iran) using the multi-stage cluster sampling method. All participants underwent optometric examinations including testing uncorrected and best-corrected distance visual acuity, non-cycloplegic autorefraction, and subjective refraction. Pentacam imaging for all participants was carried out using Pentacam AXL. Keratometry and CA were reported based on Pentacam's data. The average, standard deviation (SD) and 95% confidence interval (CI) of flat keratometry (Kf), steep keratometry (Ks), mean keratometry (mean K), and CA were 44.02 ± 1.58 D (95% CI 43.94-44.1), 44.86 ± 1.67 D (95% CI 44.78-44.94), 44.44 ± 1.58 D (95% CI 44.36-44.52), and 0.84 ± 0.74 D (95% CI 0.81-0.87), respectively. The 95% and 99% percentiles of mean K were 47.1 and 48.6 D, respectively. According to the multiple generalized estimating equation model, the mean K was significantly higher in males, in myopes, and in those with higher systolic blood pressure. Moreover, the mean K was inversely related to the axial length, height, anterior chamber depth (ACD), corneal diameter, and central corneal thickness (CCT). The prevalence of various types of CA based on a cut-off > 0.50 D was as follows; with-the-rule: 32.5% (95% CI 30.6-34.4), against-the-rule: 18.2% (95% CI 16.7-19.7), and oblique: 10.0% (95% CI 9.1-11.0). The present study investigated the normal distribution of keratometry and CA in individuals ≥ 60 years, and results can be used in clinical matters, especially in intraocular lens power calculation. Sex, systolic blood pressure, height, and some biometric components such as ACD, corneal diameter, and CCT were significantly related to keratometry and should be considered.

Scientific ReportsVol. 14(1)
Noor Eye Hospital (IR), Shahid Beheshti University of Medical Sciences (IR), Tehran University of Medical Sciences (IR)
Ministry of Health and Medical Education, National Institute for Medical Research Development
Sustainable cities and communities
Openalex Percentile: Top 20%
Corneal surgery and disorders
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.