Development and application of an algorithm to estimate the effective energy of x-rays on conventional mammography

Mammography is a radiation medical exam, which makes detection of mammary microcalcifications possible at an early stage. The dose received by the patient’s breast is known as the average glandular dose, which is considered a quality control indicator. Estimation of this parameter implies knowing the effective energy of the x-ray beam delivered. This is the case when thermoluminescent dosimetry is the method of choice. The algorithm developed to discriminate the x-ray energy the mammography patient has been exposed to while undergoing routine procedures, applies two thermoluminescent dosimeters, one of them filtered by a 1 mm thick aluminum layer. The effective energy of the x-ray beam and the correction factor are obtained by knowing the relation between the filtered and non-filtered dosemeters readout. This algorithm was then used to estimate the average glandular dose following the IAEA TRS 457 protocol. The dose values computed were compared with the international diagnostic reference levels suggested by the technical literature.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2024-08-26
DOI
https://doi.org/10.15392/2319-0612.2024.2233
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and application of an algorithm to estimate the effective energy of x-rays on conventional mammography

Pablo Andrés, Fiorela Merma Velasco, Mariela Bellotti
1 citations
Brazilian Journal of Radiation Sciences
Advanced X-ray and CT Imaging
0.18
article

Development and application of an algorithm to estimate the effective energy of x-rays on conventional mammography

Pablo Andrés, Fiorela Merma Velasco, Mariela Bellotti
article en
1 citations

Abstract

Mammography is a radiation medical exam, which makes detection of mammary microcalcifications possible at an early stage. The dose received by the patient’s breast is known as the average glandular dose, which is considered a quality control indicator. Estimation of this parameter implies knowing the effective energy of the x-ray beam delivered. This is the case when thermoluminescent dosimetry is the method of choice. The algorithm developed to discriminate the x-ray energy the mammography patient has been exposed to while undergoing routine procedures, applies two thermoluminescent dosimeters, one of them filtered by a 1 mm thick aluminum layer. The effective energy of the x-ray beam and the correction factor are obtained by knowing the relation between the filtered and non-filtered dosemeters readout. This algorithm was then used to estimate the average glandular dose following the IAEA TRS 457 protocol. The dose values computed were compared with the international diagnostic reference levels suggested by the technical literature.

Brazilian Journal of Radiation SciencesVol. 12(1A (Suppl.))
Universidad Nacional de Cuyo (AR), Balseiro Institute (AR), National University of Río Negro (AR), Comisión Nacional de Energía Atómica (AR)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 53%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.