Structural Response Analysis of Transmission Lines Steel Towers when Subjected to Nondeterministic Wind Loadings

The lattice steel towers have been widely used as supports for power transmission lines.In the current project practise, the structure's dynamic behaviour usually is not considered.Considering that many accidents associated to this kind of structure occur even for wind velocities below that specified in project, it's possible that most of these accidents have been produced by dynamic actions.This way, this investigation proposes an analysis methodology that can accurately simulate the coupled behaviour between the transmission line cables and towers, when subjected to wind nondeterministic loadings, aiming to assess the displacements and forces in the steel towers.The investigated transmission line system, including the steel towers, conductors and shield wires, presents two spans of 450 m with a 32.86 m height main suspension tower in the centre and two towers at the ends.The conclusions pointed out to quantitative differences associated to the structural response when calculated based on a static linear analysis and compared to the results considering a geometric nonlinear and nondeterministic dynamic analysis.

Authors

Publication Details

Journal
Civil-comp conferences
Published
2024-08-26
DOI
https://doi.org/10.4203/ccc.9.7.2
Citations
1
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Response Analysis of Transmission Lines Steel Towers when Subjected to Nondeterministic Wind Loadings

José Guilherme Santos da Silva, Mariana Souza Rechtman
1 citations
Civil-comp conferences
Structural Engineering and Vibration Analysis
1.43
article

Structural Response Analysis of Transmission Lines Steel Towers when Subjected to Nondeterministic Wind Loadings

José Guilherme Santos da Silva, Mariana Souza Rechtman
article en
1 citations

Abstract

The lattice steel towers have been widely used as supports for power transmission lines.In the current project practise, the structure's dynamic behaviour usually is not considered.Considering that many accidents associated to this kind of structure occur even for wind velocities below that specified in project, it's possible that most of these accidents have been produced by dynamic actions.This way, this investigation proposes an analysis methodology that can accurately simulate the coupled behaviour between the transmission line cables and towers, when subjected to wind nondeterministic loadings, aiming to assess the displacements and forces in the steel towers.The investigated transmission line system, including the steel towers, conductors and shield wires, presents two spans of 450 m with a 32.86 m height main suspension tower in the centre and two towers at the ends.The conclusions pointed out to quantitative differences associated to the structural response when calculated based on a static linear analysis and compared to the results considering a geometric nonlinear and nondeterministic dynamic analysis.

Civil-comp conferencesVol. 9
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
Affordable and clean energy
Openalex Percentile: Top 20%
Structural Engineering and Vibration Analysis
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.