Analytical Inverse Kinematics for a Prismatic-Revolute Hybrid Joints Radiography Robot Mounted on the Ambulance

Installing digital subtraction angiography (DSA) equipment in an ambulance can provide crucial image guidance for the emergency medical service of cardiovascular diseases. However, the commonly used C-arm is too large to be directly installed in a narrow ambulance. This article presents a compact redundant prismatic-revolute hybrid joints radiography robot that can be installed inside an ambulance to provide DSA imaging. An analytical solution, along with a self-motion algorithm based on the continuous quantum particle swarm algorithm, is proposed to achieve accurate motion control and real-time joint avoidance for the radiography robot. The experimental results indicate that the maximum error of the radiography robot is 0.42 mm, which meets the requirements for DSA image collection. During the in vivo experiment, DSA images provided by the radiography robot guided the successful placement of a stent in the internal thoracic artery of a beagle. This verifies the feasibility of the proposed analytical solution in ensuring accurate motion control of the radiography robot.

Authors

Institutions

Publication Details

Journal
IEEE/ASME Transactions on Mechatronics
Published
2024-08-26
DOI
https://doi.org/10.1109/tmech.2024.3442782
Citations
2
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Inverse Kinematics for a Prismatic-Revolute Hybrid Joints Radiography Robot Mounted on the Ambulance

Liming Zheng, Hao Liu, Chongyang Wang, Yaling Han et al.
2 citations
IEEE/ASME Transactions on Mechatronics
Advanced Measurement and Detection Methods
0.42
article

Analytical Inverse Kinematics for a Prismatic-Revolute Hybrid Joints Radiography Robot Mounted on the Ambulance

Liming Zheng, Hao Liu, Chongyang Wang, Yaling Han, Yang Li, Jingyang Sun, Peng Lin, Ming Liang
article en
2 citations

Abstract

Installing digital subtraction angiography (DSA) equipment in an ambulance can provide crucial image guidance for the emergency medical service of cardiovascular diseases. However, the commonly used C-arm is too large to be directly installed in a narrow ambulance. This article presents a compact redundant prismatic-revolute hybrid joints radiography robot that can be installed inside an ambulance to provide DSA imaging. An analytical solution, along with a self-motion algorithm based on the continuous quantum particle swarm algorithm, is proposed to achieve accurate motion control and real-time joint avoidance for the radiography robot. The experimental results indicate that the maximum error of the radiography robot is 0.42 mm, which meets the requirements for DSA image collection. During the in vivo experiment, DSA images provided by the radiography robot guided the successful placement of a stent in the internal thoracic artery of a beagle. This verifies the feasibility of the proposed analytical solution in ensuring accurate motion control of the radiography robot.

IEEE/ASME Transactions on MechatronicsVol. 30(2)
Shenyang Institute of Automation (CN), Chinese Academy of Sciences (CN), General Hospital of Shenyang Military Region (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 39%
Advanced Measurement and Detection Methods
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.