Noncontact Vital Sign Monitoring With FMCW Radar via Maximum Likelihood Estimation

Traditional vital sign monitoring devices typically involve direct contact with the skin using electrodes, making them unsuitable for daily vital sign monitoring due to the discomfort and skin damage. Remote detection technology provides an effective solution to these issues. This article introduces an efficient and robust algorithm for estimating vital signs using frequency-modulated continuous-wave (FMCW) radar. The integration of this method with emerging technologies, such as the Internet of Things (IoT), enables long-term and contactless vital sign monitoring, which facilitates a new model of self-management for chronic diseases and their prevention. While the breathing estimation accuracy is typically constrained by noise, heart rate (HR) estimation is primarily hindered by strong interference from the breathing signal and its higher-order harmonics. A maximum likelihood estimator based on the Newton’s method is derived and proposed in this article to accurately assess the breathing and heartbeat frequencies by enhancing the precision of vital sign parameter estimation. The proposed algorithm is validated utilizing a 77 GHz FMCW radar and compared with a reliable reference sensor. Experimental results from eight subjects demonstrate that the proposed method enhances the estimation accuracy, outperforming both conventional spectral estimation and other methods. Specifically, the root mean-square error between the reference sensor measurements and the estimations is lower than 1 beats per minute (bpm) for breathing rates and 1.5 bpm for HRs. Additionally, the Bland-Altman plots demonstrate a high level of agreement between these estimations and the reference measurements.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2024-08-26
DOI
https://doi.org/10.1109/jiot.2024.3449408
Citations
22
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
4.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noncontact Vital Sign Monitoring With FMCW Radar via Maximum Likelihood Estimation

Zhenmiao Deng, Jingyu Cong, Du Li, Shaohui Yao
22 citations
IEEE Internet of Things Journal
Non-Invasive Vital Sign Monitoring
4.06
article

Noncontact Vital Sign Monitoring With FMCW Radar via Maximum Likelihood Estimation

Zhenmiao Deng, Jingyu Cong, Du Li, Shaohui Yao
article en
22 citations

Abstract

Traditional vital sign monitoring devices typically involve direct contact with the skin using electrodes, making them unsuitable for daily vital sign monitoring due to the discomfort and skin damage. Remote detection technology provides an effective solution to these issues. This article introduces an efficient and robust algorithm for estimating vital signs using frequency-modulated continuous-wave (FMCW) radar. The integration of this method with emerging technologies, such as the Internet of Things (IoT), enables long-term and contactless vital sign monitoring, which facilitates a new model of self-management for chronic diseases and their prevention. While the breathing estimation accuracy is typically constrained by noise, heart rate (HR) estimation is primarily hindered by strong interference from the breathing signal and its higher-order harmonics. A maximum likelihood estimator based on the Newton’s method is derived and proposed in this article to accurately assess the breathing and heartbeat frequencies by enhancing the precision of vital sign parameter estimation. The proposed algorithm is validated utilizing a 77 GHz FMCW radar and compared with a reliable reference sensor. Experimental results from eight subjects demonstrate that the proposed method enhances the estimation accuracy, outperforming both conventional spectral estimation and other methods. Specifically, the root mean-square error between the reference sensor measurements and the estimations is lower than 1 beats per minute (bpm) for breathing rates and 1.5 bpm for HRs. Additionally, the Bland-Altman plots demonstrate a high level of agreement between these estimations and the reference measurements.

IEEE Internet of Things JournalVol. 11(23)
Sun Yat-sen University (CN)
National Natural Science Foundation of China, Science, Technology and Innovation Commission of Shenzhen Municipality, Science and Technology Planning Project of Guangdong Province
Climate action
Openalex Percentile: Top 5%
Non-Invasive Vital Sign Monitoring
4.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.