MixTURE: L1-Norm-Based Mixed Second-Order Continuity in Strain Tensor Ultrasound Elastography

Energy-based displacement tracking of ultrasound images can be implemented by optimizing a cost function consisting of a data term, a mechanical congruency term, and first- and second-order continuity terms. This approach recently provided a promising solution to 2-D axial and lateral displacement tracking in ultrasound strain elastography. However, the associated second-order regularizer only considers the unmixed second derivatives and disregards the mixed derivatives, thereby providing suboptimal noise suppression and limiting possibilities for total strain tensor imaging. We propose to improve axial, lateral, axial shear, and lateral shear strain estimation quality by formulating and optimizing a novel -norm-based second-order regularizer that penalizes both mixed and unmixed displacement derivatives. We name the proposed technique -MixTURE, which stands for -norm Mixed derivative for Total UltRasound Elastography. When compared with simulated ground-truth results, the mean structural similarity (MSSIM) obtained with -MixTURE ranged 0.53-0.86 and the mean absolute error (MAE) ranged 0.00053-0.005. In addition, the mean elastographic signal-to-noise ratio (SNR) achieved with simulated, experimental phantom, and in vivo breast datasets ranged 1.87-52.98, and the mean elastographic contrast-to-noise ratio (CNR) ranged 7.40-24.53. When compared with a closely related existing technique that does not consider the mixed derivatives, -MixTURE generally outperformed the MSSIM, MAE, SNR, and CNR by up to 37.96%, 67.82%, and 25.53% in the simulated, experimental phantom, and in vivo datasets, respectively. These results collectively highlight the ability of -MixTURE to deliver highly accurate axial, lateral, axial shear, and lateral shear strain estimates and advance the state-of-the-art in elastography-guided diagnostic and interventional decisions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-08-26
DOI
https://doi.org/10.1109/tuffc.2024.3449815
Citations
5
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MixTURE: L1-Norm-Based Mixed Second-Order Continuity in Strain Tensor Ultrasound Elastography

Muyinatu A. Lediju Bell, Eniola Oluyemi, Md Ashikuzzaman, Emily B. Ambinder et al.
5 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Elasticity and Material Modeling
0.92
article

MixTURE: L1-Norm-Based Mixed Second-Order Continuity in Strain Tensor Ultrasound Elastography

Muyinatu A. Lediju Bell, Eniola Oluyemi, Md Ashikuzzaman, Emily B. Ambinder, Hassan Rivaz, Kelly S. Myers, Arunima Sharma, Nethra Venkatayogi
article en
5 citations

Abstract

Energy-based displacement tracking of ultrasound images can be implemented by optimizing a cost function consisting of a data term, a mechanical congruency term, and first- and second-order continuity terms. This approach recently provided a promising solution to 2-D axial and lateral displacement tracking in ultrasound strain elastography. However, the associated second-order regularizer only considers the unmixed second derivatives and disregards the mixed derivatives, thereby providing suboptimal noise suppression and limiting possibilities for total strain tensor imaging. We propose to improve axial, lateral, axial shear, and lateral shear strain estimation quality by formulating and optimizing a novel -norm-based second-order regularizer that penalizes both mixed and unmixed displacement derivatives. We name the proposed technique -MixTURE, which stands for -norm Mixed derivative for Total UltRasound Elastography. When compared with simulated ground-truth results, the mean structural similarity (MSSIM) obtained with -MixTURE ranged 0.53-0.86 and the mean absolute error (MAE) ranged 0.00053-0.005. In addition, the mean elastographic signal-to-noise ratio (SNR) achieved with simulated, experimental phantom, and in vivo breast datasets ranged 1.87-52.98, and the mean elastographic contrast-to-noise ratio (CNR) ranged 7.40-24.53. When compared with a closely related existing technique that does not consider the mixed derivatives, -MixTURE generally outperformed the MSSIM, MAE, SNR, and CNR by up to 37.96%, 67.82%, and 25.53% in the simulated, experimental phantom, and in vivo datasets, respectively. These results collectively highlight the ability of -MixTURE to deliver highly accurate axial, lateral, axial shear, and lateral shear strain estimates and advance the state-of-the-art in elastography-guided diagnostic and interventional decisions.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(11)
Johns Hopkins University (US), Johns Hopkins Medicine (US), Concordia University (CA)
Johns Hopkins University, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 28%
Elasticity and Material Modeling
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.