Analysis of Subsynchronous Oscillations Caused by Interactions of DFIG-Based Farms and SVGs

The static var generators (SVGs) installed at the point of common coupling (PCC) of wind farms can significantly impact the sub-synchronous oscillation (SSO) performance of the power system with grid-connected wind farms. For example, in 2017 multiple SSO events were caused by interactions among a doubly fed induction generator (DFIG) based farm, constant reactive power mode (CRPM) based SVGs, and the weak grid in Xinjiang, China. This paper reveals the mechanisms of the SSO caused by the interaction among DFIG-based farms, SVGs with different control modes, and weak grids. It is discovered that CRPM-based SVGs with low current controller bandwidths (CCBWs) can suppress SSOs in the power system with grid-connected DFIG-based farms, but that constant voltage mode (CVM) based SVGs and constant power factor mode (CPFM) based SVGs can worsen the SSO performance of the system. Furthermore, it is revealed why the amplitude of the super-synchronous component is larger than the sub-synchronous component in these events by deriving their amplitude ratio equation. Finally, the theoretical analysis results are verified by the small-signal method and electromagnetic transient (EMT) simulation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Systems
Published
2024-08-26
DOI
https://doi.org/10.1109/tpwrs.2024.3449857
Citations
11
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
1.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Subsynchronous Oscillations Caused by Interactions of DFIG-Based Farms and SVGs

Xiqiang Chang, Defu Liu, Jing Qiu, Canbing Li et al.
11 citations
IEEE Transactions on Power Systems
Power Systems and Renewable Energy
1.86
article

Analysis of Subsynchronous Oscillations Caused by Interactions of DFIG-Based Farms and SVGs

Xiqiang Chang, Defu Liu, Jing Qiu, Canbing Li, Wuhui Chen, Xiaolong Guo, Kejiang Li, Wenping Qin, Wei Qin
article en
11 citations

Abstract

The static var generators (SVGs) installed at the point of common coupling (PCC) of wind farms can significantly impact the sub-synchronous oscillation (SSO) performance of the power system with grid-connected wind farms. For example, in 2017 multiple SSO events were caused by interactions among a doubly fed induction generator (DFIG) based farm, constant reactive power mode (CRPM) based SVGs, and the weak grid in Xinjiang, China. This paper reveals the mechanisms of the SSO caused by the interaction among DFIG-based farms, SVGs with different control modes, and weak grids. It is discovered that CRPM-based SVGs with low current controller bandwidths (CCBWs) can suppress SSOs in the power system with grid-connected DFIG-based farms, but that constant voltage mode (CVM) based SVGs and constant power factor mode (CPFM) based SVGs can worsen the SSO performance of the system. Furthermore, it is revealed why the amplitude of the super-synchronous component is larger than the sub-synchronous component in these events by deriving their amplitude ratio equation. Finally, the theoretical analysis results are verified by the small-signal method and electromagnetic transient (EMT) simulation.

IEEE Transactions on Power SystemsVol. 40(2)
The University of Sydney (AU), State Grid Corporation of China (China) (CN), Shanghai Jiao Tong University (CN), Taiyuan University of Technology (CN)
Zero hunger
Openalex Percentile: Top 15%
Power Systems and Renewable Energy
1.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.